首页 | 本学科首页   官方微博 | 高级检索  
检索        


Exposure of expanded polytetrafluoroethylene-wrapped hydroxyapatite orbital implant: a report of two patients
Authors:Choo P H  Carter S R  Crawford J B  Seiff S R
Institution:Department of Ophthalmology, University of California Davis, Sacramento, USA.
Abstract:PURPOSE: Hydroxyapatite (HA) spheres used to replace volume after an enucleation are often wrapped with autologous tissue before orbital implantation. Man-made materials are less expensive and pose no risk for viral transmission. The use of expanded polytetrafluoroethylene (ePTFE) to wrap HA spheres was evaluated. METHODS: The medical records of 2 consecutive patients who underwent uncomplicated implantation of an HA sphere wrapped in ePTFE were reviewed. RESULTS: An unusual reaction to the ePTFE material that was nonresponsive to topical or systemic antibiotic therapy developed in these 2 patients. Eventual wound erosion and bacterial infection of the implant necessitated its removal. CONCLUSIONS: Although well tolerated in other surgeries, ePTFE, when used to wrap HA spheres and placed into the orbit, may cause persistent conjunctival discharge, pyogenic granuloma formation, and eventual wound erosion. Therefore, the use of this material to wrap HA spheres is not recommended.
Keywords:
本文献已被 PubMed 等数据库收录!