高千伏CR与DR在尘肺病胸部摄影中应用的对比研究
引用本文:陈锋,韩扬,季成飞.高千伏CR与DR在尘肺病胸部摄影中应用的对比研究[J].中国现代医生,2014(13):83-85.
作者姓名:陈锋  韩扬  季成飞
作者单位:[1]杭州市余杭区疾病预防控制中心,浙江杭州311100 [2]杭州市预防保健门诊部,浙江杭州310014 [3]浙江大学医学院,浙江杭州310058
基金项目:浙江省卫生厅医药卫生重点资助基金(2012ZDA011)
摘    要:目的探讨高千伏计算机X线摄影(CR)与直接数字X线摄影(DR)在尘肺病胸部摄影中的临床应用价值,比较其优片率和检出率差异。方法选取2011年5月~2013年5月期间我中心确诊的尘肺病患者78例进行回顾性分析,按数字表法随机分为两组。其中对照组38例患者采用高千伏CR胸片进行检查;而观察组40例患者采用高千伏DR胸片进行检查,由我中心专业的具有尘肺病诊断资格的临床医师独立读片并对比分析.比较两种检查方法的优片率和检出率。结果观察组患者的检查优片率为92.50%,明显高于对照组的84.21%(P〈0.05):观察组对于尘肺病的总检出率为95.00%,也显著高于对照组的86.84%(P〈0.05)。结论高千伏DR技术摄片能够为尘肺病诊断提供更客观准确的信息,其优片率和检出率远远高于高千伏CR技术摄片,可作为尘肺病早期筛查的有效方法。值得在临床上推广使用。

关 键 词:计算机X线摄影  直接数字X线摄影  高千伏  优片率  检出率

The comparative study of high kV CR and DR for the diagnosis of pneu- moconiosis chest radiography
Authors:CHEN Feng  HAN Yang  JI Chengfei
Institution:1.Yuhang District Center for Disease Control and Prevention, Hangzhou City, Zhejiang, Hangzhou 311100,China; 2. Hangzhou City Preventive Health Care Clinics, Zhejiang, Hangzhou 310014,China; 3.Zhejiang University School of Medicine, Zhejiang, Hangzhou 310058,China)
Abstract:Objective To explore the application effect of high kV CR and DR for the diagnosis of pneumoconiosis chest radiography. Compare the differences of their excellent piece rate and detection rate. Methods The 78 cases pa- tients diagnosed with pneumoconiosis during the period from May 2011 to May 2013 in our center were retrospectively analyzed and randomly divided into two groups based on the method of number table.The 38 patients of the control group used the high high-kilovolt X-ray photography computer (CR) chest ;while the 40 patients of the observation group used the high-kilovolt direct digital X-ray radiography (DR) chest.And select the professional clinicians of our center to analyze, read and compare the differences of the excellent piece rate and detection rate of the two methods. Results Thepatients checking excellent piece rate of the observation group was 92.50%,significantly higher than the 84.21% of the control group.What's more,for the detection rate of pneumoconiosis of the observation group was 95.00% ,also significantly higher than the 86.84% of the control group, difference were statistically significant (P〈 0.05). Conclusion The High kV radiography DR technology can provide more objective and accurate diagnosis of pneumoconiosis information which excellent piece rate and detection rate are both higher than the high kV radiography CR technology. It can be used as an effective method for early screening of pneumoconiosis, which is worthy of use in clinical practice.
Keywords:Computer X-ray photography  Direct digital X-ray photography  High kV  Excellent chip rate  Detection rate