医院消毒灭菌效果的监测与分析 |
| |
引用本文: | 胡玮,应瑶蓉,占利. 医院消毒灭菌效果的监测与分析[J]. 中国现代医生, 2014, 0(12): 122-124 |
| |
作者姓名: | 胡玮 应瑶蓉 占利 |
| |
作者单位: | [1]宁波市第二医院消毒供应中心,浙江宁波315010 [2]宁波市李惠利医院消毒供应室,浙江宁波315040 [3]浙江省疾病预防控制中心,浙江杭州310051 |
| |
基金项目: | 浙江省医药卫生平台骨干人才计划(2011RCB014) |
| |
摘 要: | 目的 监测医院消毒供应室的消毒灭菌效果和质量,为完善医院消毒灭菌工作提供可靠的理论依据.方法 开展“消毒供应室消毒灭菌效果监测”活动,主要对我院消毒供应室的压力蒸汽灭菌器、清洗效果、消毒质量三个项目进行监测,监测结果判断标准参考《医院消毒卫生标准》中的医院卫生标准及各仪器使用标准.结果 医院消毒供应室在压力蒸汽灭菌器监测项目中,BD实验监测合格率为100%,工艺监测项目合格率为100%,化学监测项目合格率为100%;在清洗效果监测项目中,清洗机性能监测合格率为96.67%,清洗机清洗效果监测合格率为93.33%,手工清洗效果监测合格率为96.40%;在消毒质量监测项目中,湿热消毒质量监测合格率为91.30%,化学消毒质量监测合格率为90.20%,器具消毒效果监测合格率为87.60%.结论 本院消毒供应室的整体消毒灭菌效果良好,在今后的工作中应进一步加强管理,加大规范操作技术,加强对医疗手术卫生设施的资金投入,降低医院感染发生率.
|
关 键 词: | 消毒供应室 消毒灭菌 监测 |
Monitoring and analysis of the hospital disinfection sterilization effect |
| |
Affiliation: | HU Wei YING Yaorons ZHAN LP (1.Disinfection Supply Center, the Second Hospital of Ningbo City in Zhejiang Province, Ningbo 315010; China; 2.Disinfection Supply Room, Lihuili Hospital of Ningbo Medical Center in Zhejiang Province, Ningbo 315040, China; 3.Zhejiang Center for Disease Control and Prevention, Hangzhou 310051, China) |
| |
Abstract: | Objective To monitor the disinfection effect and quality of the hospital disinfection supply room, analysis to perfect the hospital disinfection work provides reliable theoretical basis. Methods Carried out the disinfection supply room disinfection sterilization effect monitoring activities, mainly in our hospital disinfection supply room of the pressure steam sterilizer, cleaning effect, disinfection quality of three monitoring project, monitoring results judgment standard reference" the health standard for hospital disinfection "hospital hygiene standards and instruments used in the standard. Results Hospital disinfection supply room in the measurement of the pressure steam sterilizer in the project, BD experiment monitoring percent of pass was 100%, the process monitoring of the project qualified rate was 100%, the chemical monitoring project percent of pass was 100%; In cleaning effect monitoring project, cleaner performance monitoring of the percent of pass was 96.67%, 93.33%; cleaner cleaning effect monitoring, monitoring manual cleaning effect was 96.40%; In hot wet disinfection disinfection quality monitoring testing project, quality monitoring, percent of pass was 91.30% percent of pass was 90.20% chemical disinfection quality monitoring, utensils disinfection effect monitoring percent of pass was 87.60%. Conclusion Our hospital disinfection supply room in the whole disinfection sterilization effect is good, in the future should further strengthen the work of management, and increase the technology of standard operation, to strengthen medical operations funded health facilities, reduce the incidence of hospital infection. |
| |
Keywords: | Disinfection supply room Disinfection sterilization Monitoring |
本文献已被 维普 等数据库收录! |
|