首页 | 本学科首页   官方微博 | 高级检索  
检索        

中医常见脉象的血液动力学参数分析
引用本文:郭睿,王忆勤,燕海霞,颜建军,李福凤.中医常见脉象的血液动力学参数分析[J].上海中医药大学学报,2010(6):26-29.
作者姓名:郭睿  王忆勤  燕海霞  颜建军  李福凤
作者单位:[1]上海中医药大学四诊信息综合实验室,上海201203 [2]华东理工大学机械电子工程中心,上海200237
基金项目:国家“十一五”科技支撑计划资助项目(2006BAI08B01-04); 上海市教委重点学科(第3期)建设资助项目(S30302);上海市教委科研创新项目(11YZ71); 上海市高校优秀青年教师选拔基金资助项目(szy07032); 上海市优秀学科带头人计划资助项目(09XD1403700)
摘    要:目的:寻找具有生理病理意义的脉象特征,为脉象的识别开辟一个新的研究思路。方法:共收集337例样本,其中弦脉129例、平脉93例和滑脉115例,对这些样本的脉图进行谐波分析,并利用血液动力学原理来估算弦脉、滑脉和平脉的血液动力学参数波速和反射系数的特征。结果:弦脉的波速v落在v≥13.241 m/s的范围内,平脉的波速落在5.64≤v≤9.742 m/s范围内,滑脉的波速大多数落在4.3≤v≤10 m/s范围内;弦脉的反射系数R落在R≥0.75范围内,平脉的反射系数大多数落在0.4≤R≤0.7范围内,滑脉的反射系数大多数落在0.1R≤0.45范围内。结论:中医常见脉象(弦、滑、平脉)的血液动力学参数(波速、反射系数)分布具有一定的规律,因为脉搏波的波速和反射系数直接与血管弹性、血液黏度、外周阻力等生理参数相关,所以认为波速和反射系数可视为具有生理、病理意义的脉象特征,用于脉象的识别。

关 键 词:血液动力学  波速  反射系数  脉象  谐波分析

Analysis on Hemodynamic Parameters of Common Pulses of TCM
GUO Rui,WANG Yi-qin,YAN Hai-xia,YAN Jian-jun,LI Fu-feng.Analysis on Hemodynamic Parameters of Common Pulses of TCM[J].Acta Universitatis Traditionis Medicalis Sinensis Pharmacologiaeque Shanghai,2010(6):26-29.
Authors:GUO Rui  WANG Yi-qin  YAN Hai-xia  YAN Jian-jun  LI Fu-feng
Institution:1.Comprehensive Laboratory of Four Diagnostic Methods,Shanghai University of Traditional Chinese Medicine2.School of Mechanical and Power Engineering,East China University of Science and Technology
Abstract:Objective: To look for pulse features with physiological and pathological significance and open a new research clue on pulse recognition in TCM.Methods: 337 cases were collected,including 129 cases of wiry pulse,93 cases of plain pulse and 115 cases of slippery pulse.All of the pulse conditions were analyzed by harmonic analysis to evaluate the features of wave velocity and reflection coefficient of plain pulse,wiry pulse and slippery pulse on the basis of hemodynamic principles.Results: The range of wave velocity(v) of wiry pulse was v≥13.241 m/s,the plain pulse was 5.64≤v≤9.742 m/s,and the majority of slippery pulse was 4.3≤v≤10 m/s.The range of reflection coefficient(R) of wiry pulse was R≥0.75,the majority of plain pulse was 0.4≤R≤0.7,and the majority of slippery pulse was 0.1R≤0.45.Conclusion: There lies a law in the distribution of wave velocity and reflection coefficient of plain pulse,wiry pulse and slippery pulse,and the wave velocity and reflection coefficient has connection with the blood vessel elasticity,viscosity of blood,peripheral resistance and other physiological parameters,thus the wave velocity and reflection coefficient can be considered as features of pulse with physiological and pathological significance for distinguishing pulses.
Keywords:Hemodynamics  wave velocity  reflection coefficient  states of pulse  harmonic analysis
本文献已被 CNKI 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号