首页 | 本学科首页   官方微博 | 高级检索  
     

辐照对尼可刹米注射液含量的影响
引用本文:李卓恒,藕顺龙,管海燕,于彩平,李沉纹,卢来春. 辐照对尼可刹米注射液含量的影响[J]. 中国药房, 2013, 0(48): 4591-4593
作者姓名:李卓恒  藕顺龙  管海燕  于彩平  李沉纹  卢来春
作者单位:第三军医大学大坪医院野战外科研究所药剂科,重庆400042
摘    要:目的:建立测定尼可刹米注射液中主药含量的方法,并考察其吸收不同强度的γ射线辐照后含量的变化。方法:采用高效液相色谱法。色谱柱为Diamonsil Technology C18柱,流动相为甲醇-水(50:50,V/V),流速为1ml/min,检测波长为263nm,柱温为30℃.进样量为20μl。将同一批号的尼可刹米注射液放置于^60Co-γ射线放射源中,一次性吸收2、4、8、16、26、34kGy的辐照剂量后检测药物含量,并与辐照前比较。结果:尼可刹米检测质量浓度在12-36μg/ml范围内与峰面积积分值呈良好的线性关系(r=0.9998);日间(n=5)及日内精密度(n=3)均小于2%;低、中、高质量浓度的平均加样回收率分别为100.64%、98.69%、101.15%。辐照8、16、26、34kGy时其含主药的量显著低于辐照前,与辐照前比较差异有统计学意义(P〈0.05)。结论:该方法可用于尼可刹米注射液中主药的含量测定;辐照对尼可刹米注射液的含量及稳定性有一定影响。

关 键 词:尼可刹米注射液  辐照  高效液相色谱法  含量测定

Effects of Irradiation on the Content of Nikethamide Injection
LI Zhuo-heng,OU Shun-long,GUAN Hai-yan,YU Cai-ping,LI Chen-wen,LU Lai-chun. Effects of Irradiation on the Content of Nikethamide Injection[J]. China Pharmacy, 2013, 0(48): 4591-4593
Authors:LI Zhuo-heng  OU Shun-long  GUAN Hai-yan  YU Cai-ping  LI Chen-wen  LU Lai-chun
Affiliation:(Dept. of Pharmacy, Institute for Field Surgery, Daping Hospital of Third Military Medical University, Chongqing 400042, China)
Abstract:OBJECTIVE: To develop a method for the content determination of nikethamide in Nikethamide injection, and to study the changes of Nikethamide injection after 3,-ray irradiation in different intensity levels. METHODS: HPLC method was adopted. The determination was performed on Diamonsil Technology C18 with mobile phase consisted of methanol-water (50:50, V/V) at the flow rate of 1 ml/min. The detection wavelength was set at 263 nm, and the column temperature was 30 ℃. The injection volume was 20 μl. The same batch of Nikethamide injection put in the ^60Co-γ, ray with radiation dose of 2, 4, 8, 16, 26, 34 kGy by one-time, compared with before radiation. RESULTS: The linear range of nikethamide was 12-36 μg/ml (r= 0.999 8); RSD of intra-day (n=5) and inter-day (n=3) were lower than 2%. The average recoveries of low, medium and high concentrations were 100.64%, 98.69% and 101.15%, respectively. The amounts of main components after 8, 16, 26 and 34 kGy irradiation were significantly lower than before; there was statistical significance (P〈0.05). CONCLUSIONS: The develop method can be used for the content determination of nikethamide in Nikethamide injection; and the irradiation has impact on the stability of Nikethamide injection to some extent.
Keywords:Nikethamide injection  Irradiation  HPLC  Content determination
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号