The Effect of Endodontic Irrigants on the Microtensile Bond Strength of Dentin Adhesives |
| |
Authors: | Haktan Yurdagüven Jale Tanalp Burcu Toydemir Kambiz Mohseni Mübin Soyman Gündüz Bayirli |
| |
Affiliation: | 1. Department of Operative Dentistry, Yeditepe University;2. Department of Endodontics, Yeditepe University;3. Private Practice |
| |
Abstract: | IntroductionThe purpose of this study was to evaluate the microtensile bond strength of a total etch (XP-Bond) and a self-etch (Clearfil SE Bond) adhesive system to dentine surfaces treated using endodontic irrigants.MethodsTwenty-four freshly extracted third molars were used. After creating a smear layer on the coronal midthird portion of the crowns, the teeth were divided into three groups and surfaces were irrigated with distilled water, 5.25% NaOCl + 17% EDTA, and 1.3% NaOCl + BioPure MTAD, respectively. Each group was divided into two subgroups, and a self-etching adhesive and an etch-and-rinse adhesive were applied respectively. The teeth were restored with a composite material and sectioned to produce sticks for microtensile bond testing.ResultsThe microtensile bond strength of the MTAD + Clearfil SE group was found to be significantly lower than the microtensile bond strength of the distilled water + Clearfil SE Bond group and the NaOCl, EDTA, + Clearfil SE Bond group (p = 0.0001, p = 0.009).ConclusionsBecause of the significant reduction of Clearfil SE Bond to coronal dentine after MTAD application, an etch-and rinse adhesive such as XP-Bond may be preferred if this irrigant has been chosen during endodontic treatment. |
| |