首页 | 本学科首页   官方微博 | 高级检索  
     


Echo Particle Image Velocimetry for Estimation of Carotid Artery Wall Shear Stress: Repeatability,Reproducibility and Comparison with Phase-Contrast Magnetic Resonance Imaging
Authors:Arati Gurung  Phillip E. Gates  Luciano Mazzaro  Jonathan Fulford  Fuxing Zhang  Alex J. Barker  Jean Hertzberg  Kunihiko Aizawa  William D. Strain  Salim Elyas  Angela C. Shore  Robin Shandas
Affiliation:1. Department of Bioengineering, University of Colorado Denver, Aurora, Colorado, USA;2. Diabetes and Vascular Medicine, University of Exeter Medical School, Exeter, UK;3. Department of Mechanical Engineering, University of Colorado Boulder, Boulder, Colorado, USA
Abstract:Measurement of hemodynamic wall shear stress (WSS) is important in investigating the role of WSS in the initiation and progression of atherosclerosis. Echo particle image velocimetry (echo PIV) is a novel ultrasound-based technique for measuring WSS in vivo that has previously been validated in vitro using the standard optical PIV technique. We evaluated the repeatability and reproducibility of echo PIV for measuring WSS in the human common carotid artery. We measured WSS in 28 healthy participants (18 males and 10 females, mean age: 56 ± 12 y). Echo PIV was highly repeatable, with an intra-observer variability of 1.0 ± 0.1 dyn/cm2 for peak systolic (maximum), 0.9 dyn/cm2 for mean and 0.5 dyn/cm2 for end-diastolic (minimum) WSS measurements. Likewise, echo PIV was reproducible, with a low inter-observer variability (max: 2.0 ± 0.2 dyn/cm2, mean: 1.3 ± 0.1 dyn/cm2, end-diastolic: 0.7 dyn/cm2) and more variable inter-scan (test–retest) variability (max: 7.1 ± 2.3 dyn/cm2, mean: 2.9 ± 0.4 dyn/cm2, min: 1.5 ± 0.1 dyn/cm2). We compared echo PIV with the reference method, phase-contrast magnetic resonance imaging (PC-MRI); echo PIV-based WSS measurements agreed qualitatively with PC-MRI measurements (r = 0.89, p < 0.05). Significant differences were observed in some WSS measurements (echo PIV vs. PC-MRI): WSS at peak systole: 21 ± 7.0 dyn/cm2 vs. 15 ± 5.0 dyn/cm2; time-averaged WSS: 8.9 ± 3.0 dyn/cm2 vs. 7.1 ± 3.0 dyn/cm2 (p < 0.05); WSS at end diastole: 3.8 ± 2.8 dyn/cm2 vs. 3.9 ± 2 dyn/cm2 (p > 0.05). For the first time, we report that echo PIV can measure WSS with good repeatability and reproducibility in adult humans with a broad age range. Echo PIV is feasible in humans and offers an easy-to-use, ultrasound-based, quantitative technique for measuring WSS in vivo in humans with good repeatability and reproducibility.
Keywords:Echo pulse imaging velocimetry  Ultrasound imaging velocimetry  Measurement uncertainty  Phase-contrast magnetic resonance imaging  Atherosclerosis  Plaque rupture
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号