首页 | 本学科首页   官方微博 | 高级检索  
检索        

可调式口腔矫治器治疗睡眠呼吸暂停综合征后患者的上气道形态变化
引用本文:郭彪,路荣建.可调式口腔矫治器治疗睡眠呼吸暂停综合征后患者的上气道形态变化[J].北京口腔医学,2020(2):107-111.
作者姓名:郭彪  路荣建
作者单位:解放军总医院第五医学中心(南院区)口腔科
基金项目:首都临床特色应用研究(Z171100001017192)。
摘    要:目的比较可调式口腔矫治器治疗不同程度阻塞性睡眠呼吸暂停综合征(OSAS)患者前后上气道三维形态的变化。方法采用可调式口腔矫治器对多导睡眠监测仪及白天嗜睡量表诊断为OSAS的36例患者进行治疗,戴用4个月时,比较不同程度OSAS患者治疗前后舌咽、腭咽等不同部位上气道形态在CBCT下的变化。结果相比治疗前,在戴用可调式矫治器4个月时,轻度OSAS患者腭咽和舌咽各部位的变化值均有统计学意义;对于中度OSAS患者,除腭咽段最小横径变化,及舌咽段最小横径和最小截面积变化外,其余变化均有统计意义;重度OSAS患者腭咽和舌咽各部位的变化值均无统计学意义。结论可调式矫治器治疗轻中度OSAS患者,气道变化明显;对于重度OSAS患者来说,气道改善不明显。

关 键 词:可调式口腔矫治器  睡眠呼吸暂停综合征  上气道形态  CBCT

Morphological changes of upper airway in patients with different degrees of obstuctive sleep apnea syndrome treated with adjustable oral appliance
GUO Biao,LU Rong-jian.Morphological changes of upper airway in patients with different degrees of obstuctive sleep apnea syndrome treated with adjustable oral appliance[J].Beijing Journal Of Stomatology,2020(2):107-111.
Authors:GUO Biao  LU Rong-jian
Institution:(Department of Stomatology(South Campus),The Fifth Medical Center of the PLA General Hospital,Beijing 100071,China)
Abstract:Objective To compare the three-dimensional morphological changes of upper airways under cone-beam CT(CBCT) in patients with different degrees of OSAS treated with adjustable oral appliance. Methods Thirty-six patients diagnosed with OSAS by polysomnography and daytime sleepiness scale were treated with adjustable oral appliance for four months.The morphological changes of glossopharyngeal and palatopharyngeal before and after treatment in patient with different degrees of OSAS patients under CBCT were compared. Results After treatment with adjustable oral appliance,the morphological changes of glossopharyngeal and palatopharyngeal in patients with mild OSAS were statistically significant. In patients with moderate OSAS, except for the change of the minimum transverse diameter of the palatopharyngeal segment and the change of the minimum transverse diameter and the minimum cross-sectional area of the glossopharyngeal segment, the other changes were statistically significant. There was no significant change in the morphology of glossopharyngeal and palatopharyngeal in patients with severe OSAS. Conclusion The airway morphological change was significant for patients with mild to moderate OSAS treated with adjstable appliances and not significant for patients with severe OSAS.
Keywords:Adjustable oral appliance  Obstructive sleep apnea syndrome  Upper airway morphology  CBCT
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号