首页 | 本学科首页   官方微博 | 高级检索  
     


Safety and performance of the EverProTM everolimus-eluting coronary stent system with biodegradable polymer in a real-world scenario
Authors:Rahul Trimukhe  Preeti Vani  Arvind Patel  Vikas Salgotra
Affiliation:Rahul Trimukhe, Department of Cardiology, Atma Malik Hospital, Ahmednagar 423601, Maharashtra, IndiaPreeti Vani, Vikas Salgotra, SLTL Medical Division, SLTL (Sahajanand Laser Technology Ltd.), Gandhinagar 382016, Gujarat, IndiaArvind Patel, SLTL Group, SLTL (Sahajanand Laser Technology Ltd.), Gandhinagar 382016, Gujarat, India
Abstract:BACKGROUNDThe EverProTM (Sahajanand Laser Technology Ltd., India) everolimus-eluting coronary stent system (EES) is a second-generation drug-eluting stent with a biodegradable polymer.AIMTo determine the safety and performance of the EverProTM EES in patients with coronary artery disease (CAD) during a 1-year clinical follow-up.METHODSThis observational, retrospective, single-center study enrolled patients who had been implanted with the EverProTM stent between June 1, 2018 and January 31, 2019, and had completed a 1-year follow-up period after the index procedure. The primary clinical endpoint was major adverse cardiac events (MACE) at 6 mo defined as the composite of cardiac death, myocardial infarction (MI), and target lesion revascularization (TLR). Secondary endpoints were the incidence of TLR at 1, 6 and 12 mo follow-up, MACE at 1 and 12 mo follow-up, and stent thrombosis up to 1 year after the index procedure.RESULTSThe study population comprised 77 patients (98 lesions). A total of 37 (48.1%) patients had comorbid hypertension. In total, 26 (33.8%) patients presented with ST segment elevation MI and 10.4% patients with non-ST segment elevation MI. Treated lesions were located mainly in the left anterior descending artery (49%) followed by the right coronary artery (29.6%), left circumflex (12.2%) and obtuse marginal (9.2%) arteries. The majority of patients were with single-vessel disease (79%), 22.2% of lesions had a mild to severe thrombus load, and 94.9% were American College of Cardiology/American Heart Association type B or C. De novo stenting was performed in 96.9% of patients and 3% were treated for in-stent restenosis. Procedural success was attained in all patients. In-hospital or follow-up MACE and stent thrombosis were not reported during the 1-year follow-up period.CONCLUSIONThese findings suggest that the EverProTM EES is a safe and effective treatment option with no MACE or stent thrombosis reported during the 1-year study period in patients with CAD.
Keywords:Coronary artery disease   Everolimus   Major adverse cardiac event   Retrospective   EverProTM   Myocardial infarction
点击此处可从《World journal of cardiology》浏览原始摘要信息
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号