首页 | 本学科首页   官方微博 | 高级检索  
     


Assessment of ductal blood flow in newborns with obstructive left heart lesions by cardiovascular magnetic resonance
Authors:Marcelo Felipe Kozak  Shi-Joon Yoo  Luc Mertens  Ashley Ho  Lars Grosse-Wortmann
Affiliation:1.Labatt Family Heart Centre in the Department of Paediatrics and Department of Diagnostic Imaging, The Hospital for Sick Children, University of Toronto, Toronto, ON, Canada
Abstract:

Background

Newborns with obstructive left heart lesions often depend on a patent ductus arteriosus to sustain the systemic circulation. Our aims were to validate the direct measurement of ductal flow, and to characterize the magnitude, determinants and hemodynamic effects of patent ductus arteriosus in newborns with obstructive left heart lesions by cardiovascular magnetic resonance (CMR).

Methods

In this retrospective study, the CMR and clinical information of newborns with obstructive left heart lesions were reviewed. The feasibility and validity of measuring ductal flow and the correlations between ductal flow and ventricular volumes, ascending aortic flow, post-ductal oxygen saturation and Qp:Qs were assessed.

Results

The CMR examinations of 32 newborns were included. It was possible to measure the ductal flow in all of them, with moderate-to-good agreement between measured and calculated ductal flow volume. The flow was bidirectional in all patients, with a net right-to-left shunt in 72%. Net ductal flow correlated inversely with ascending aortic flow (Rho −0.63; p 0.0002), post-ductal oxygen saturation (Rho −0.58; p 0.0004), Qp:Qs (Rho −0.43; p 0.02), and with left ventricular end-diastolic volume index (Rho −0.38; p 0.04). There was no correlation with the diameter of the ductus. The contribution of ductus flow to the systemic circulation correlated with the left ventricular end-diastolic volume index (Rho −0.47; p 0.02).

Conclusions

Direct measurement of ductal flow in newborns with obstructive left heart lesions is feasible. From these measurements, we were able to demonstrate that patients with smaller left ventricles and lower ascending aortic flow have a greater contribution of ductal flow to the systemic circulation. The size of the ductus arteriosus does not predict net ductal flow. Phase-contrast CMR can be an adjunct method for the assessment of the physiology for very ill neonate patients.
Keywords:Patent ductus arteriosus   Flow   Cardiovascular magnetic resonance   Obstructive   Newborn   Congenital heart disease
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号