摘    要:本文比较了斑点酶联免疫吸附试验(Dot-ELISA)检测循环抗原,间接血凝试验(IHA)、环卵沉淀试验(COPT)检测抗体诊断血吸虫病的效果。12例急性血吸虫病患者血清3种方法检测均为阳性;277例慢性血吸虫病患者血清3种方法检测阳性率分别为79.42%、64.62%和63.18%。14例华支睾吸虫病患者血清和89例健康人血清Dot-ELISA检测均为阴性。10例急性血吸虫病患者,在离开流行区经吡喹酮治疗后37周时粪检全部转阴,检测血清循环抗原4例转阴,其余6例滴度大幅度下降;IHA检测3例转阴,其余7例几何平均倒数滴度(GMRT)由47.57降至9.35;COPT检测平均环沉率由21.5%降至4.12%。结果表明Dot-ELISA检测血吸虫循环抗原具有较好的敏感性和特异性。这3种方法在血吸虫病诊断及疗效考核中均有一定价值。

关 键 词:血吸虫病,循环抗原,斑点酶联免疫吸附试验,间接血凝试验,环卵沉淀试验

COMPARISON OF DOT-ELISA FOR DETECTING CIRCULATING ANTIGEN WITH IHA, COPT FOR DETECTING ANTIBODY FROM SCHISTOSOMIASIS PATIENT
Li Shu- Hua,Liu Li- Ming Hubei Instituteof Schistosomiasis Control.COMPARISON OF DOT-ELISA FOR DETECTING CIRCULATING ANTIGEN WITH IHA, COPT FOR DETECTING ANTIBODY FROM SCHISTOSOMIASIS PATIENT[J].Journal of Pathogen Biology,1995(2).
Authors:Li Shu- Hua  Liu Li- Ming Hubei Instituteof Schistosomiasis Control
Institution:Wuhan 430070
Abstract:The comparison of Dot- ELISA used for detecting circulating antigen with IHA,COPT trials for detecting antibody were made on schistosomiasis patient. With the three methodsof Dot- ELISA, IHA and COPT,all 12 sera from acute schistosomiasis patients were positive,while the positive rate of277 sera from chronic schstosomiasis patients by the three methodswere 79. 42%, 66and6 18%respectively. The positive rate of Dot-ELISA for detectingcirculatingantigen was higher than of IHA and COPT for detecting antibody(P<0. 01 ).All 14sera from Clonorchis sinensis patients and 89 normal sera were negative by Dot- ELISA,4 serafrom 10acute schistosomiasis patients, who were negative with stool examination after leavingendemic area and 37 weeks after treatment with praziquantel, became negative with Dot- ELISA : In the other 6 cases GMRT declined from 705. 02 before treatment to 4. 92 after treat-ment; Only 3 cases were negative by IHA and GMRT of other 7 cases came down from 47. 57 be-fore treatment to 9. 35 after treatment ; 4 cases were detected with COPT and the rates of circum-oval precipitin were below 3%, the circumoval precipitin rates of 2 cases were 1%; Average pre-cipitin rate decreased from 21.5?fore treatment to 4. 12?ter treatment. The results of Dot- ELISA showed higher sensitivity and specificity for the detection of circulating antigen. Dot- ELISA, COPT and IHA were of value for effective evaluation of schistosomiasis treatment.