首页 | 本学科首页   官方微博 | 高级检索  
     

髋关节区动脉支架植入治疗下肢动脉重症缺血的临床效果评价
引用本文:张曦彤,韩向军,张伟,刘大伟,梁松年,夏永辉,牛猛. 髋关节区动脉支架植入治疗下肢动脉重症缺血的临床效果评价[J]. 中华介入放射学电子杂志, 2015, 3(4): 186-190. DOI: 10.3877/cma.j.issn.2095-5782.2015.04.003
作者姓名:张曦彤  韩向军  张伟  刘大伟  梁松年  夏永辉  牛猛
作者单位:1. 110001 沈阳,中国医科大学附属第一医院介入放射科
摘    要:目的观察与评价髋关节区支架植入治疗下肢动脉重症缺血的安全性、有效性及对股深动脉血流的影响。 方法66例动脉硬化闭塞所致下肢重症缺血患者(共70条动脉,均累及股总动脉和/或股动脉近心段)。平均年龄74.6岁。男46例,女20例。左下肢动脉40条,右下肢动脉30条。开通闭塞动脉后,行球囊扩张及支架植入。 结果术中股动脉急性闭塞3例(局部溶栓后获得通畅),余下肢动脉即刻血流均获得通畅,下肢缺血症状均明显改善。术后15例患肢出现血流过度灌注,无严重并发症发生。随访54例(失访12例),随访时间2~30个月,平均(16.2±2.6)个月。25例因再狭窄或闭塞发生患肢缺血,其中16例接受再次介入治疗(PTA及导管溶栓后获二次通畅)。跨髋关节支架均无断裂,股深动脉均仍保持通畅。6例发生心、脑血管意外,其中2例死亡。 结论跨髋关节动脉支架植入可安全、有效地改善下肢动脉重症缺血,且不影响股深动脉血流。

关 键 词:动脉硬化闭塞,下肢  球囊扩张  支架  
收稿时间:2015-08-15

Evaluation of the clinical effects on the treatment of arterial stent placement across hip joint for critical lower extremity ischemia
Xitong Zhang,Xiangjun Han,Wei Zhang,Dawei Liu,Songnian Liang,Yonghui Xia,Meng Niu. Evaluation of the clinical effects on the treatment of arterial stent placement across hip joint for critical lower extremity ischemia[J]. Chinese Journal of Interventional Radiology (Electronic Edition), 2015, 3(4): 186-190. DOI: 10.3877/cma.j.issn.2095-5782.2015.04.003
Authors:Xitong Zhang  Xiangjun Han  Wei Zhang  Dawei Liu  Songnian Liang  Yonghui Xia  Meng Niu
Affiliation:1. Department of Radiology, the First Hospital of China Medical University, Shenyang 110001, China
Abstract:ObjectiveTo evaluate the clinical safety and effect of arterial stent placement across hip joint for critical lower extremity ischemia and observe the influence of the stent on femoral profound artery patency. MethodsSixty-six patients (male 46, female 20) who aged 50-88 years (mean 74.6 years) with critical lower extremity ischemia caused by arteriosclerosis occlusion were reviewed in our study. The total 70 arterial lesions involved the common femoral arteries and/or proximal SFAs. The angioplasty and stents placement after successful canalization was performed in left (40 limbs) and right lower extremity arteries (30 limbs). ResultsThe acute thrombosis occurred in three SFAs during the operation, but was dissolved by catheter directed thrombolysis. The other arteries got patency immediately. All ischemia were improved obviously. Fiveteen patients had blood hyper-perfusion in implicated limbs but no severe complication occurred. The follow-up time were (16.2±2.6) months (2-30 months) among 54 cases, the other 12 cases were lost to follow-up. The ischemia due to stenosis or occlusion recurred in 25 cases. Among them, 16 patients received the re-interventional therapy (PTA or catheter directed thrombolysis) and got satisfactory results. In all stents across the hip joint, no fracture occurred and the femoral profound arteries were still patency proved by CTA and DSA examination. Two of six patients with cardiac arrest or stoke died during the follow-up. ConclusionsArterial stents placement across hip joint is a safe and effective therapy for critical lower extremity ischemia, and the fluency of femoral profound artery is not affected.
Keywords:Arteriosclerosis occlusion   lower extremity  Angioplasty  Stent  
点击此处可从《中华介入放射学电子杂志》浏览原始摘要信息
点击此处可从《中华介入放射学电子杂志》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号