Quantitation of esophageal transit by means of 81mKr |
| |
Authors: | Hamphrey R. Ham Amnon Piepsz Bernard Georges Jean Verelst Marcel Guillaume Samy Cadranel |
| |
Affiliation: | (1) Department of Radioisotope, St. Peter Hospital, Free University of Brussels, Belgium;(2) Department of Pediatrics, St. Peter Hospital, Free University of Brussels, Belgium;(3) Centre de Recherche de Cyclotron, University of Liege, Belgium;(4) Department of Radioisotope, St. Peter Hospital, Rue Haute 322, 1000 Brussels, Belgium |
| |
Abstract: | A method for quantifying esophageal transit by means of 81mKr is described. The principal advantage of 81mKr compared with 99mTc is its ultra-short half-life with its consequences on radiation dose and counting statistics. Factors which may influence the esophageal transit time such as body posture, volume of the tracer, and the nature of the tracer were studied. The reproducibility of the technique is quite good and its capacity to detect minor esophageal transit disorders is demonstrated. |
| |