首页 | 本学科首页   官方微博 | 高级检索  
     


Differential removal of human pathogenic viruses from sewage by conventional and ozone treatments
Authors:Hao Wang  Per Sikora  Carolin Rutgersson  Magnus Lindh  Tomas Brodin  Berndt Björlenius  D.G. Joakim Larsson  Heléne Norder
Affiliation:1. Department of Infectious Diseases, Institute of Biomedicine at Sahlgrenska Academy, University of Gothenburg, 41346 Gothenburg, Sweden;2. Department of Pathology and Genetics, Institute of Biomedicine at Sahlgrenska Academy, University of Gothenburg, 41345 Gothenburg, Sweden;3. Clinical Genomics Gothenburg, SciLife Labs, Gothenburg, Sweden;4. Centre for Antibiotic Resistance Research (CARe) at University of Gothenburg, Sweden;5. Department Ecology and Environmental Science, Umeå University, Umeå, Sweden;6. Division of Industrial Biotechnology, KTH Royal Institute of Technology, AlbaNova University Center, SE-106 91 Stockholm, Sweden
Abstract:Sewage contains a mixed ecosystem of diverse sets of microorganisms, including human pathogenic viruses. Little is known about how conventional as well as advanced treatments of sewage, such as ozonation, reduce the environmental spread of viruses. Analyses for viruses were therefore conducted for three weeks in influent, after conventional treatment, after additional ozonation, and after passing an open dam system at a full-scale treatment plant in Knivsta, Sweden. Viruses were concentrated by adsorption to a positively charged filter, from which they were eluted and pelleted by ultracentrifugation, with a recovery of about 10%. Ion Torrent sequencing was used to analyze influent, leading to the identification of at least 327 viral species, most of which belonged to 25 families with some having unclear classification. Real-time PCR was used to test for 21 human-related viruses in inlet, conventionally treated, and ozone-treated sewage and outlet waters. The viruses identified in influent and further analyzed were adenovirus, norovirus, sapovirus, parechovirus, hepatitis E virus, astrovirus, pecovirus, picobirnavirus, parvovirus, and gokushovirus. Conventional treatment reduced viral concentrations by one to four log10, with the exception of adenovirus and parvovirus, for which the removal was less efficient. Ozone treatment led to a further reduction by one to two log10, but less for adenovirus. This study showed that the amount of all viruses was reduced by conventional sewage treatment. Further ozonation reduced the amounts of several viruses to undetectable levels, indicating that this is a promising technique for reducing the transmission of many pathogenic human viruses.
Keywords:Waste water  Next generation sequencing  Effluent  Adenovirus  Parvovirus
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号