首页 | 本学科首页   官方微博 | 高级检索  
     


Is DDD Superior to VVI Pacing in Mixed Carotid Sinus Syndrome? An Acute and Medium-Term Study
Authors:MICHELE BRIGNOLE  BRUNO SARTORE  MAURO BARRA  CARLO MENOZZI    GINO LOLLI
Affiliation:Laboratory of Electrophysiology and Pacemaker Implant, Service of Cardiology, Hospital of Lavagna, Italy;Division of Cardiology, Hospital of Reggio Emilia, Italy
Abstract:The aim of this study was to evaluate fhe importance of atrial synchronism for pacing therapy of patients with mixed carotid sinus syndrome. In 23 patients (21 m, two f: mean age 69 ± 8 years) affected by symptomatic mixed carotid sinus syndrome we performed: (1) Research of ventriculo-atrial conduction, orthostatic hypotension and pacemaker effect; and [2] Carotid sinus massage in the standing position during VVI and DVI temporary pacing. Next, ail patients received a permanent DDD pacemaker and entered a 2 month two period single-blind, randomized, cross-over study on DVI/DDD versus VVI mode. During the DVI/DDD period, no syncope occurred in any patients, minor symptoms persisted in 11 (48%) of them; during VVI period syncopes recurred in three patients, symptoms requiring the withdrawal of VVI pacing and premature DVI/DDD reprogramming in eight patients, minor symptoms in 17 (74%). A comparison between 14 patients, who preferred DVI/DDD period (Group A), and the remaining nine patients who noted no preference between DVI/DDD and VVI period (Group B) was performed on the basis of the preimplant evaluation. Group A patients had a greater pacemaker effect (-34 ± 16 mmHg vs -16 ± 14 mmHg) and a higher prevalence of symptomatic pacemaker effect (50% vs 0%), of ventriculo-atrial conduction (78% vs 44%) and of orthostatic hypotension (50% vs 11%), while the entity of the systolic pressure fall caused by carotid sinus massage was similar in the two groups either during VVI mode (Group A-51 ± 16 mmHg vs Group B-56 ± 27 mmHg) or DVI mode (Group A-38 ± 17 mmHg vs Group 3–45 ± 17 mmHg). Thus, we conclude that vasodepressor reflex of carotid sinus syndrome is not prevented by DVI/DDD pacing even if the loss of atrial synchronism resulting from WI pacing, by adding an important pacemaker effect, causes a more severe hemodynamic consequence. DVI/DDD pacing is more effective than VVI in 61% of patients. When pacemaker effect, ventriculoatrial conduction and orthostatic hypotension are present, VVI failure is possible, therefore DVI/DDD stimulation is indicated; on the contrary the evaluation of the vasodepressor reflex during WJ or DVI temporary pacing is of little value in the choice of the mode of pacing.
Keywords:carotid sinus syndrome    carotid sinus massage    pacemaker effect    ventriculo-atrial conduction    electro-stimulation
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号