摘    要:目的 探讨畸变产物耳声发射测试对噪声性聋的诊断价值。方法 对115名军人(204耳)进行DPOAE幅值测试,采用两个等强度L1=L2=70dB SPL的纯音信号f1、f2=1.2。测试1、2、4kHz和6kHz DPOAE幅值,根据DPOAE幅值是否大于或小于标准值,判断听力正常与否。并同纯音听阈进行对照。结果 1、2、4和6kHz各频率的敏感度分别是70%、67%、85%和73%;特异度分别是71%、66%、84%和75%。结论 DPOAE幅值测试用于诊断噪声性聋,缺乏足够的敏感性和特异性,单一的DPOAE幅值测试,不能诊断噪声性聋。

关 键 词:噪声性  耳听力下降  畸变产物耳声发射
文章编号:1006-7299(2001)04-0219-03
修稿时间:2001年3月5日

Distortion Product Otoacoustic Emission Test of Noise Induced Hearing Loss: Performance Regarding Sensitivity and Specificity
Guo Hongguang,Qian Jin,Jiang Wei,et al..Distortion Product Otoacoustic Emission Test of Noise Induced Hearing Loss: Performance Regarding Sensitivity and Specificity[J].Journal of Audiology and Speech Pathology,2001,9(4):219-221.
Authors:Guo Hongguang  Qian Jin  Jiang Wei  
Abstract:Objective To study the clinical efficacy of screening for noise induced hearing loss(NIHL) with distortion product otoacoustic emissions(DPOAE).Methods DPOAEs were recorded in 204 ears of 115 military personnel with the stimulus levels of the two tones equal to 70 dB SPL and the ratio between the two frequencies 1.2.In the DPOAE test, the cochlear function of one ear at a test frequency was predicted to be normal or abnormal depending upon whether the DPOAE level with the geometric mean of the two stimulus frequencies at test frequency was greater or less than a criterion. The DPOAE test outcomes were evaluated against the pure tone threshold as the standard. Results We found the sensitivity and specificity of the test to be 70%, 67%, 85%,73% and 71%, 66%, 84%, 75%, at 1,2,4,and 6 kHz respectively. Conclusion DPOAEs are not sufficiently sensitive to serve as a single test to identify NIHL.
Keywords:Screening Noise induced hearing loss(NIHL) Distortion product otoacoustic emission
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号