首页 | 本学科首页   官方微博 | 高级检索  
检索        

高效液相色谱法同时测定多维元素片中的维生素B2和叶酸
引用本文:车宁,梁晓丽,邹金凯,金鹏飞,胡欣,邹定.高效液相色谱法同时测定多维元素片中的维生素B2和叶酸[J].中国药学杂志,2012,47(15):1250-1253.
作者姓名:车宁  梁晓丽  邹金凯  金鹏飞  胡欣  邹定
作者单位:卫生部北京医院药学部
基金项目:中央保健科研课题专项资金资助(B2009B032)
摘    要: 目的 应用高效液相色谱建立多维元素片中维生素B2和叶酸的同时测定方法。 方法 以0.5%氨水溶液为提取液,采用Alltima C18色谱柱(4.6 mm×250 mm, 5 μm),以50 mmol·L-1磷酸二氢铵溶液(磷酸调至pH 3.0)-乙腈(85∶15)为流动相,流速0.5 mL·min-1,检测波长为282 nm。结果 在本方法中,维生素B2和叶酸分别在11.52~34.56和2.952~8.856 mg·L-1内线性关系良好,相关系数(r)都大于0.999 9;2种成分和药品中其他成分以及强制降解产物之间均有良好的分离度;2种成分精密度实验的相对标准偏差(RSD)均小于2.0%;3个加样浓度的百分回收率都在97.95%和102.3%之间;常温下各种溶液中2种成分都在8 h内保持稳定。方法学比较显示:该方法和《美国药典》方法测定结果具有很好的一致性。结论 该方法准确、简单、快速,可作为多维元素片中维生素B2和叶酸的同时测定方法。

关 键 词:高效液相色谱法  多维元素片  维生素B2  叶酸  水溶性维生素
收稿时间:2012-08-21;

Simultaneous Determination of Vitamin B2 and Folic Acid in Multivitamin with Multimineral Tablets by HPLC
CHE Ning,LIANG Xiao-li,ZOU Jin-kai,JIN Peng-fei,HU Xin,ZOU Ding.Simultaneous Determination of Vitamin B2 and Folic Acid in Multivitamin with Multimineral Tablets by HPLC[J].Chinese Pharmaceutical Journal,2012,47(15):1250-1253.
Authors:CHE Ning  LIANG Xiao-li  ZOU Jin-kai  JIN Peng-fei  HU Xin  ZOU Ding
Institution:(Department of Pharmaceutical Science,Beijing Hospital,Beijing 100730,China)
Abstract:OBJECTIVE To establish an HPLC method for simultaneous determination of vitamin B2 and folic acid in Multivitamin with Multimineral Tablets.METHODS The samples were extracted with 0.5%(V/V) ammonia solution.An Alltima C18 column(4.6 mm×250 mm,5 μm) was used for the separation with 50 mmol·L-1 ammonium dihydrogen phosphate(adjusted pH to 3.0 with H3PO4) and acetonitrile(85∶15) as the mobile phase at the flow rate of 0.5 mL·min-1.The detection wavelength was 282 nm.RESULTS The method showed good linearity for vitamin B2 and folic acid with both correlation coefficients(r) greater than 0.999 9 in the ranges of 11.52-34.56 and 2.952-8.856 mg·L-1,respectively;the specificity study showed satisfactory resolutions between vitamin B2,folic acid,other ingredients and forced degradation products;the precisions were satisfactory with both relative standard deviations(RSD) lower than 2.0%;the spiked recoveriesy at three levels ranged from 97.95% to 102.3% for both compounds;the stability at ambient temperature was acceptable within 8 h for both compounds in combined standard solutions and analytical solutions.Method comparison indicated coincident results between this method and the USP method.CONCLUSION This method is an accurate,fast and simple method for the simultaneous determination of vitamin B2 and folic acid in Multivitamin with Multimineral Tablets.
Keywords:HPLC  multivitamin with multimineral tablets  vitamin B2  folic acid  water-soluble vitamins