首页 | 本学科首页   官方微博 | 高级检索  
     


Biomechanical researches on tissue engineering bone constructed by deproteinated bone
Authors:JIAN Yue-kui  TIAN Xiao-bin  LI Qi-hong  LI Bo  PENG Zhi  ZHAO Wei-feng  WANG Yuan-zheng  YANG Zhen
Affiliation:[1]Department of Orthopaedics, Guizhou Provincial People's Hospital, Guiyang 550002, China [2]Center for Joint Surgery, Southwest Hospital, Third Military Medical University, Chongqing 400038, China
Abstract:Objective:To study biomechanical changes of newly formed bones 24 weeks after repairing large defects of long bones of goats using heterogeneous deproteinated bone(DPB)prepared by modified methods as an engineering scaffold.Methods:According to a fully randomized design,18 goats were evenly divided into three groups:normal bone control group(Group A),autologous bone group(Group B)and experimental group(Group C).Each goat in Groups B and C were subjected to the periosteum and bone defect at middle-lower part of the fight tibia(20% of the whole tibia in length),followed by autologous bone or DPB plus autologous MSCs + rhBMP2 implantation,respectively and semiring slot fixation;while goats in Group A did not perform osteotomy.At 24 weeks after surgery,biomechanical tests were carried out on the tibias.Results:At 24 weeks after surgery,the results of anticompression test on tibias in three groups were recorded by a functional recorder presented as linear pressure-deformation curve.The shapes of the curves and their change tendency were similar among three groups.The ultimate pressure values were 10.74 Mpa±1.23 Mpa,10.11 Mpa±1.35 Mpa and 10.22 Mpa±1.32 Mpa and fracture compression rates were 26.82%±0.87%,27.17%±0.75% and 28.22%±1.12% in Groups A,B and C,respectively.Comparisons of anti-compression ultimate pressures and fracture compression rates among three groups demonstrated no significant difference(P_(AB)=0.415,P_(BC)=0.494).Three-point antibend test on tibias was recorded as load-deformation curves,and the shapes of the curves and their change tendency were similar among three groups.The ultimate pressure values of the anti-bend test were 481.52 N±12.45 N,478.34 N±14.68 N and 475.62 N±13.41 N and the fracture bend rates were 2.62 mm±0.12 mm,2.61 mm±0.15 mm and 2.81 mm±0.13 mm in Groups A,B and C,respectively.There was no significant difference between groups(P_(AB)=0.7,P_(BC)=0.448).The ultirates were 29.51°±1.64°,28.88°±1.46° and 28.81°±1.33° in Groups A,B and C,respectively.There was no significant difference between groups(P_(AB)=0.123,P_(BC)=0.346).Conclusions:The biomechanical characteristics of newly formed bones from heterogeneous DPB for repairing large segmental long bone defect are comparable to those of normal bones and autologous bones.DPB has the potential for clinical usage as bone graft material.
Keywords:Biomechanics  Tissue engineering  Deproteinated bone
本文献已被 维普 万方数据 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号