首页 | 本学科首页   官方微博 | 高级检索  
     


Automatic segmentation of pelvic structures from magnetic resonance images for prostate cancer radiotherapy
Authors:Pasquier David  Lacornerie Thomas  Vermandel Maximilien  Rousseau Jean  Lartigau Eric  Betrouni Nacim
Affiliation:Département Universitaire de Radiothérapie, Centre Oscar Lambret, Université Lille II, Lille, France. d-pasquier@o-lambret.fr
Abstract:PURPOSE: Target-volume and organ-at-risk delineation is a time-consuming task in radiotherapy planning. The development of automated segmentation tools remains problematic, because of pelvic organ shape variability. We evaluate a three-dimensional (3D), deformable-model approach and a seeded region-growing algorithm for automatic delineation of the prostate and organs-at-risk on magnetic resonance images. METHODS AND MATERIALS: Manual and automatic delineation were compared in 24 patients using a sagittal T2-weighted (T2-w) turbo spin echo (TSE) sequence and an axial T1-weighted (T1-w) 3D fast-field echo (FFE) or TSE sequence. For automatic prostate delineation, an organ model-based method was used. Prostates without seminal vesicles were delineated as the clinical target volume (CTV). For automatic bladder and rectum delineation, a seeded region-growing method was used. Manual contouring was considered the reference method. The following parameters were measured: volume ratio (Vr) (automatic/manual), volume overlap (Vo) (ratio of the volume of intersection to the volume of union; optimal value = 1), and correctly delineated volume (Vc) (percent ratio of the volume of intersection to the manually defined volume; optimal value = 100). RESULTS: For the CTV, the Vr, Vo, and Vc were 1.13 (+/-0.1 SD), 0.78 (+/-0.05 SD), and 94.75 (+/-3.3 SD), respectively. For the rectum, the Vr, Vo, and Vc were 0.97 (+/-0.1 SD), 0.78 (+/-0.06 SD), and 86.52 (+/-5 SD), respectively. For the bladder, the Vr, Vo, and Vc were 0.95 (+/-0.03 SD), 0.88 (+/-0.03 SD), and 91.29 (+/-3.1 SD), respectively. CONCLUSIONS: Our results show that the organ-model method is robust, and results in reproducible prostate segmentation with minor interactive corrections. For automatic bladder and rectum delineation, magnetic resonance imaging soft-tissue contrast enables the use of region-growing methods.
Keywords:Image segmentation   Deformable organ models   Radiotherapy   Treatment planning   Prostate cancer   MRI
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号