Oral implant surfaces: Part 2--review focusing on clinical knowledge of different surfaces |
| |
Authors: | Albrektsson Tomas Wennerberg Ann |
| |
Institution: | Department of Biomaterials/Handicap Research, Institute for Surgical Sciences, G?teborg University, Sweden. tomas.albrektsson@biomaterials.gu.se |
| |
Abstract: | PURPOSE: This article reviews clinical knowledge of selected oral implant surfaces. MATERIALS AND METHODS: The surfaces most commonly used in clinical practice, marketed by the five largest oral implant companies, are identified; their clinical documentation was scrutinized following a strict protocol. Experimental knowledge of the surfaces is briefly summarized. Retrospective, prospective, and comparative clinical studies were analyzed separately, as were studies of implants in conjunction with bone grafts. RESULTS: TiUnite anodized surfaces are clinically documented in 1- to 2-year follow-up studies at best, with failures at about 3%. Sandblasted and acid-etched SLA surfaces are documented with good clinical results for up to 3 years. Osseotite dual acid-etched implants are documented with good clinical results for up to 5 years. Frialit-2 sandblasted and etched implants are positively documented for about 3 years in one study only. The Tioblast implant is the only design documented for survival over 10 years of follow-up and success over 7 years of follow-up. CONCLUSION: Generally, oral implants are introduced clinically without adequate clinical documentation. Implant companies initiate clinical documentation after product launch. The standards of clinical reporting have improved over the years. Proper long-term reports have been published for only one surface, Tioblast. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|