首页 | 本学科首页   官方微博 | 高级检索  
检索        

实时三维超声心动图诊断二尖瓣关闭不全
引用本文:袁新春,张诚,周爱云,陈莉.实时三维超声心动图诊断二尖瓣关闭不全[J].中国医学影像技术,2016,32(7):1052-1055.
作者姓名:袁新春  张诚  周爱云  陈莉
作者单位:南昌大学第一附属医院超声科, 江西 南昌 330006,南昌大学第一附属医院超声科, 江西 南昌 330006,南昌大学第一附属医院超声科, 江西 南昌 330006,南昌大学第一附属医院超声科, 江西 南昌 330006
摘    要:目的 探讨经胸实时三维超声心动图(RT-3DE)诊断二尖瓣关闭不全的价值。方法 随机选取95例经手术确诊的二尖瓣关闭不全患者,对所有患者术前均行二维超声及RT-3DE检查,并与手术结果进行对比,评价二者诊断准确率的差异。结果 对95例患者均成功采集RT-3DE图像。95例中,风湿性心脏病二尖瓣狭窄合并二尖瓣关闭不全48例,二维超声与RT-3DE对其诊断准确率均为100%(48/48);二维超声与RT-3DE诊断二尖瓣脱垂、二尖瓣腱索断裂、二尖瓣瓣裂、二尖瓣穿孔的准确率的差异均有统计学意义(P均<0.05)。结论 RT-3DE操作简便,成像速度快,三维图像细致,诊断准确率高于二维超声,是二尖瓣外科手术治疗前重要的检测手段。

关 键 词:超声心动描记术  三维  二尖瓣病变  二尖瓣关闭不全

Real-time three-dimensional echocardiography in diagnosis of mitral insuffciency
YUAN Xinchun,ZHANG Cheng,ZHOU Aiyun and CHEN Li.Real-time three-dimensional echocardiography in diagnosis of mitral insuffciency[J].Chinese Journal of Medical Imaging Technology,2016,32(7):1052-1055.
Authors:YUAN Xinchun  ZHANG Cheng  ZHOU Aiyun and CHEN Li
Institution:Department of Ultrasound, the First Affiliated Hospital of Nanchang University, Nanchang 330006, China,Department of Ultrasound, the First Affiliated Hospital of Nanchang University, Nanchang 330006, China,Department of Ultrasound, the First Affiliated Hospital of Nanchang University, Nanchang 330006, China and Department of Ultrasound, the First Affiliated Hospital of Nanchang University, Nanchang 330006, China
Abstract:Objective To explore the application value of real-time three-dimensional echocardiography (RT-3DE) technology in the diagnosis of mitral insuffciency. Methods Ninety-five hospitalized patients with mitral insuffciency underwent the conventional two-dimensional echocardiography and RT-3DE images. Then the comparison with surgical results was made to evaluate the accuracy. Results The three-dimensional images of 95 patients were successfully captured by RT-3DE. Among them, 48 patients suffered rheumatic heart disease mitral valve lesion. The diagnostic accuracy of the conventional two-dimensional echocardiography and RT-3DE were 100% (48/48). The differences of accuracy in diagnosis of non rheumatic mitral insufficiency, mitral chordae tendineae fracture crack, mitral valve prolapse and mitral valve perforation were statistically significant (all P<0.05). Conclusion The RT-3DE is easily operated that features as fast imaging, clear three-dimension and high diagnostic accuracy, which provides an important preoperative examination for mitral valve surgery.
Keywords:Echocardiography  three-dimensional  Mitral disease  Mitral insuffciency
点击此处可从《中国医学影像技术》浏览原始摘要信息
点击此处可从《中国医学影像技术》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号