摘    要:目的:为了评价微柱凝胶技术(MGCT)检测抗-D效价。方法:用MGCT和试管抗球蛋白实验(TCT)同时检测38例孕妇血清抗-D效价。结果:MGCT检测抗-D效价高于TCT 2~6滴度(平均提高3~4个滴度),MGCT检测抗-D效价灵敏度显著高于TCT,差异有统计学意义(P〈O.01)结论:MGCT法检测抗-D效价是一种灵敏度较高的方法。

关 键 词:微柱凝胶技术  抗一D  抗体效价  新生儿溶血病

Comparison of conventional tube test with Diamed gel microcolumn assay for anti-D titration
TANG Haiyan. Comparison of conventional tube test with Diamed gel microcolumn assay for anti-D titration[J]. Journal of Clinical Hematology, 2011, 24(3): 344-345
Authors:TANG Haiyan
Affiliation:TANG Haiyan(Department of Clinical Laborarory,Renming Hospital of Huangpi District,Wuhan,430300,China)
Abstract:Objective:To evaluate gel microcolumn assay for anti-D titration.Method:38 known blood samples with anti-D(titers:1-32) were titrated simultaneously by the conventional tube test and the gel microcolumn assay.Result:Anti-D titration in the gel microcolumn assay showed significantly higher titers(mean 3~4-fold) than that in the conventional tube test in all samples studied.Conclusion:The gel microcolumn assay may be a highly sensitive test in examining the level of anti-D titers,it was not possible to determ...