首页 | 本学科首页   官方微博 | 高级检索  
检索        


U-turn speed is a valid and reliable smartphone-based measure of multiple sclerosis-related gait and balance impairment
Institution:1. F. Hoffmann-La Roche Ltd, Basel, 4070, Switzerland;2. Department of Neurosciences, University of California, San Diego, San Diego, CA, 92093, USA;3. University of California, San Francisco, San Francisco, CA, 94143, USA;4. Division of Neurology, University of Toronto, Toronto, ON, M5S 1A1, Canada;5. Department of Neurology-Neuroimmunology, Multiple Sclerosis Centre of Catalonia (CEMCAT), Vall d’Hebron University Hospital, Barcelona, 08035, Spain;6. Department of Economics, Baden-Wuerttemberg Cooperative State University, Loerrach, 79539, Germany
Abstract:BackgroundPeople living with multiple sclerosis (MS) experience impairments in gait and mobility, that are not fully captured with manually timed walking tests or rating scales administered during periodic clinical visits. We have developed a smartphone-based assessment of ambulation performance, the 5 U-Turn Test (5UTT), a quantitative self-administered test of U-turn ability while walking, for people with MS (PwMS).Research questionWhat is the test-retest reliability and concurrent validity of U-turn speed, an unsupervised self-assessment of gait and balance impairment, measured using a body-worn smartphone during the 5UTT?Methods76 PwMS and 25 healthy controls (HCs) participated in a cross-sectional non-randomised interventional feasibility study. The 5UTT was self-administered daily and the median U-turn speed, measured during a 14-day session, was compared against existing validated in-clinic measures of MS-related disability.ResultsU-turn speed, measured during a 14-day session from the 5UTT, demonstrated good-to-excellent test-retest reliability in PwMS alone and combined with HCs (intraclass correlation coefficient ICC] = 0.87 95 % CI: 0.80–0.92]) and moderate-to-excellent reliability in HCs alone (ICC = 0.88 95 % CI: 0.69–0.96]). U-turn speed was significantly correlated with in-clinic measures of walking speed, physical fatigue, ambulation impairment, overall MS-related disability and patients’ self-perception of quality of life, at baseline, Week 12 and Week 24. The minimal detectable change of the U-turn speed from the 5UTT was low (19.42 %) in PwMS and indicates a good precision of this measurement tool when compared with conventional in-clinic measures of walking performance.SignificanceThe frequent self-assessment of turn speed, as an outcome measure from a smartphone-based U-turn test, may represent an ecologically valid digital solution to remotely and reliably monitor gait and balance impairment in a home environment during MS clinical trials and practice.
Keywords:Consumer wearable technology  Digital health  Gait and balance impairment  Multiple sclerosis  Turning while walking  Turn speed  Smartphone  Accelerometer  Gyroscope
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号