首页 | 本学科首页   官方微博 | 高级检索  
检索        


Anterior cruciate ligament reconstruction with 4-strand hamstring autograft and accelerated rehabilitation: a 10-year prospective study on clinical results, knee osteoarthritis and its predictors
Authors:Rob P A Janssen  Arthur W F du Mée  Juliette van Valkenburg  Harm A G M Sala  Carroll M Tseng
Institution:1. Orthopaedic Center Máxima, Máxima Medical Center, Postbus 90052, 5600 PD, Eindhoven, The Netherlands
2. Department of Radiology, Máxima Medical Center, Postbus 90052, 5600 PD, Eindhoven, The Netherlands
Abstract:

Purpose

Analysis of long-term clinical and radiological outcomes after anterior cruciate ligament (ACL) reconstruction with special attention to knee osteoarthritis and its predictors.

Methods

A prospective, consecutive case series of 100 patients. Arthroscopic transtibial ACL reconstruction was performed using 4-strand hamstring tendon autografts with a standardized accelerated rehabilitation protocol. Analysis was performed preoperatively and 10 years postoperatively. Clinical examination included Lysholm and Tegner scores, IKDC, KT-1000 testing (MEDmetric Co., San Diego, CA, USA) and leg circumference measurements. Radiological evaluation included AP weight bearing, lateral knee, Rosenberg and sky view X-rays. Radiological classifications were according to Ahlbäck and Kellgren & Lawrence. Statistical analysis included univariate and multivariate logistic regressions.

Results

Clinical outcome A significant improvement (p < 0.001) between preoperative and postoperative measurements could be demonstrated for the Lysholm and Tegner scores, IKDC patient subjective assessment, KT-1000 measurements, pivot shift test, IKDC score and one-leg hop test. A pivot shift phenomenon (glide) was still present in 43 (50 %) patients and correlated with lower levels of activity (p < 0.022). Radiological outcome: At follow-up, 46 (53.5 %) patients had signs of osteoarthritis (OA). In this group, 33 patients (72 %) had chondral lesions (≥grade 2) at the time of ACL reconstruction. A history of medial meniscectomy before or at the time of ACL reconstruction increased the risk of knee OA 4 times (95 % CI 1.41–11.5). An ICRS grade 3 at the time of ACL reconstruction increased the risk of knee OA by 5.2 times (95 % CI 1.09–24.8). There was no correlation between OA and activity level (Tegner score ≥6) nor between OA and a positive pivot shift test.

Conclusion

Transtibial ACL reconstruction with 4-strand hamstring autograft and accelerated rehabilitation restored anteroposterior knee stability. Clinical parameters and patient satisfaction improved significantly. At 10-year follow-up, radiological signs of OA were present in 53.5 % of the subjects. Risk factors for OA were meniscectomy prior to or at the time of ACL reconstruction and chondral lesions at the time of ACL reconstruction.

Level of evidence

II.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号