首页 | 本学科首页   官方微博 | 高级检索  
     


Gadolinium-enhanced 3D MR angiography of renal artery stenosis: a pilot comparison of maximum intensity projection, multiplanar reformatting, and 3D volume-rendering postprocessing algorithms
Authors:Baskaran Visveshwar  Pereles F Scott  Nemcek Albert A  Carr James C  Miller Frank H  Ly John  Krupinski Elizabeth  Finn J Paul
Affiliation:Department of Radiology, Northwestern University, Northwestern Memorial Hospital, Chicago, IL 60611, USA.
Abstract:RATIONALE AND OBJECTIVES: The authors compared diagnostic accuracy of maximum intensity projection (MIP), multiplanar reformatting (MPR), and three-dimensional (3D) volume rendering (VR) in the evaluation of gadolinium-enhanced 3D magnetic resonance (MR) angiography of the renal arteries. They hypothesized that VR is as accurate as or more accurate than MIP and MPR at depicting renal artery stenosis. MATERIALS AND METHODS: The study group comprised 28 consecutive patients who underwent gadolinium-enhanced 3D MR angiography of the renal arteries. Studies were postprocessed to display images in MIP, MPR, and VR formats. Digital subtraction angiography (DSA), when performed (nine of 28 patients), was the standard for comparison. For each main renal artery, an estimate of percentage stenosis was made for any stenoses detected by three independent radiologists. For calculation of sensitivity, specificity, and accuracy, MR angiographic stenosis estimates were categorized as mild (0%-39%), moderate (40%-69%), or severe (> or = 70%). DSA stenosis estimates of 70% or greater were considered hemodynamically significant. RESULTS: Analysis of variance demonstrated MIP estimates of stenosis were statistically greater than VR estimates in two readers and greater than MPR estimates in all readers for all patients. MIP images also showed the largest mean difference from DSA stenosis estimates for all three readers. For both VR and MPR, mean differences between MR angiographic stenoses estimates and DSA estimates reached significance for only one reader, whereas, for MIP versus DSA, mean differences reached significance for all three readers. Although not statistically significant compared with DSA, accuracies of VR (87%) and MPR (89%) were greater than that of MIP (81%). CONCLUSION: In this pilot study, MIP was the least accurate of the three image display algorithms tested. VR and MPR yielded similar values for each method of comparison.
Keywords:Angiography, comparative studies   magnetic resonance (MR), vascular studies   renal arteries, magnetic resonance (MR)   renal arteries, stenosis or obstruction
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号