首页 | 本学科首页   官方微博 | 高级检索  
     

The Effects of Lower Intensity Anticoagulation Therapy on Coagulation System in Patients With Mechanical Prosthetic Valves
引用本文:杜心灵,张凯伦,胡志伟,蓝鸿钧,罗军,金咏梅. The Effects of Lower Intensity Anticoagulation Therapy on Coagulation System in Patients With Mechanical Prosthetic Valves[J]. 华中科技大学学报(医学英德文版), 1999, 19(1): 56-58. DOI: 10.1007/BF02895598
作者姓名:杜心灵  张凯伦  胡志伟  蓝鸿钧  罗军  金咏梅
作者单位:DU Xinling,ZHANG Kailun,HU Zhiwei,LAN Hongjun LUO Jun,JIN Yongmei Department of Cardiovascular Surgery,Xiehe Hospital Tongji Medical University,Wuhan 430022
摘    要:Thelowerintensityanticoagulationtherapyhasinterestedclinicianssincetheintroductionofnewgenerationmechanicalprostheticvalvesin...


The effects of lower intensity anticoagulation therapy on coagulation system in patients with mechanical prosthetic valves
Du Xinling,Zhang Kailun,Hu Zhiwei,Lan Hongjun,Luo Jun,Jin Yongmei. The effects of lower intensity anticoagulation therapy on coagulation system in patients with mechanical prosthetic valves[J]. Journal of Huazhong University of Science and Technology. Medical sciences, 1999, 19(1): 56-58. DOI: 10.1007/BF02895598
Authors:Du Xinling  Zhang Kailun  Hu Zhiwei  Lan Hongjun  Luo Jun  Jin Yongmei
Affiliation:(1) Department of Cardiovascular Surgery, Xiehe Hospital, Tongji Medical University, 430022 Wuhan
Abstract:Summary  To evaluate the effect of lower intensity anticoagulation therapy in patients with mechanical prosthetic valves, laboratory-based hematological assays including prothrombin time (PT), activity of factor X, antithrombinI (ATI), D-dimer, fibrinogen (Fg) and platel et al pha-granular membrane protein (GMP-140) were performed in 65 patients who had been on warfarin treatment for over one month. The patients were assigned to 3 groups on the basis of their International Normalized Ratios (INR), ranging from 2.00 to 2.50; 2.51 to 3.00; 3.01 to 4.50, respectively. The results showed that the D-dimer, Fg, GMP-140 levels were higher after mechanical valve replacement than those before operation, indicating, the activation of coagulation and fibrinolysis system and the damage of platelets. Lower intensity anticoagulation therapy (INR 2.00 to 2.50) could effectively inhibit the activity of factor X and increase the level of ATI. There were no appreciable differences among D-dimer, Fg, GMP-140 and ATI in the 3 anticoagulation intensity groups. These results suggest that in patients with new generation mechanical prosthetic valves, target anticoagulation level (INR 2.00 to 2.50) may result in good protection from thrombo-embolism.
Keywords:anticoagulation intensity  coagulation system  mechanical prosthetic valve
本文献已被 CNKI SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号