首页 | 本学科首页   官方微博 | 高级检索  
     


Reliable HPLC method for therapeutic drug monitoring of frequently prescribed tricyclic and nontricyclic antidepressants
Authors:Malfará Wilson Roberto  Bertucci Carlo  Costa Queiroz Maria Eugênia  Dreossi Carvalho Sonia Ap  Pires Bianchi Maria de Lourdes  Cesarino Evandro José  Crippa José Alexandre  Costa Queiroz Regina Helena
Affiliation:1. Department of Clinical, Toxicologic and Bromatologic Analyses, Faculty of Pharmaceutical Sciences of Ribeirão Preto, University of São Paulo, Brazil;2. Department of Chemistry, University of São Paulo, Brazil;3. Department of Psychiatry and Psycology, Faculty of Medicine of Ribeirão Preto, University of São Paulo, Brazil;4. Department of Pharmaceutical Sciences, University of Bologna, Italy
Abstract:A new high-performance liquid chromatography method is presented for the determination of 10 frequently prescribed tricyclic and nontricyclic antidepressants: imipramine, amitriptyline, clomipramine, fluoxetine, sertraline, paroxetine, citalopram, mirtazapine, moclobemide and duloxetine. The simple and accurate sample preparation step, consisted of liquid:liquid extraction with recoveries ranging between 72% and 86%, except for moclobemide (59%). Separation was obtained using a reverse phase Select B column under isocratic conditions with UV detection (230 nm). The mobile phase consisted of 35% of a mixture of acetonitrile/methanol (92:8, v/v) and 65% of 0.25 mol L(-1) sodium acetate buffer, pH 4.5. The standard curves were linear over a working range of 2.5-1000 ng mL(-1) for moclobemide, 5-2000 ng mL(-1) for citalopram, duloxetine, fluoxetine, 10-2000 ng mL(-1) for sertraline, imipramine, paroxetine, mirtazapine and clomipramine. The intra-assay and inter-assay precision and accuracy were studied at three concentrations (50, 200, and 500 ng mL(-1)). The intra-assay coefficients of variation (CVs) for all compounds were less than 8.8%, and all inter-CVs were less than 10%. Limits of quantification were 2.5 ng mL(-1) for moclobemide, 5 ng mL(-1) for citalopram, duloxetine and amitriptyline, and 10 ng mL(-1) for mirtazapine, paroxetine, imipramine, fluoxetine, sertraline, and clomipramine. No interference of the drugs normally associated with antidepressants was observed. The method has been successfully applied to the analysis of real samples, for the drug monitoring of ten frequently prescribed tricyclic and non-tricyclic antidepressant drugs.
Keywords:Therapeutic drug monitoring   Tricyclic   Nontricyclic antidepressants   HPLC UV detection
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号