首页 | 本学科首页   官方微博 | 高级检索  
检索        


Reproducibility of scoring emphysema by HRCT
Authors:Malinen A  Erkinjuntti-Pekkanen R  Partanen K  Rytkönen H  Vanninen R
Institution:  a Departments of Clinical Radiology. b Pulmonary Diseases, Kuopio University Hospital, Kuopio, Finland..
Abstract:Purpose: We evaluated the reproducibility of three visual scoring methods of emphysema and compared these methods with pulmonary function tests (VC, DLCO, FEV1 and FEV%) among farmer's lung patients and farmers.Material and Methods: Three radiologists examined high-resolution CT images of farmer's lung patients and their matched controls (n=70) for chronic interstitial lung diseases. Intraobserver reproducibility and interobserver variability were assessed for three methods: severity, Sanders' (extent) and Sakai. Pulmonary function tests as spirometry and diffusing capacity were measured.Results: Intraobserver κ-values for all three methods were good (0.51-0.74). Interobserver κ varied from 0.35 to 0.72. The Sanders' and the severity methods correlated strongly with pulmonary function tests, especially DLCO and FEV1.Conclusion: The Sanders' method proved to be reliable in evaluating emphysema, in terms of good consistency of interpretation and good correlation with pulmonary function tests.
Keywords:Lung  High-resolution Ct  Emphysema  Farmer's Lung  Observer Performance