Usefulness of myocardial performance index for assessing right ventricular function after percutaneous closure of atrial septal defect
Authors:Jingdong Ding  Genshan Ma  Yaoyao Huang  Xiaoli Zhang  Jian Zhu  Rong Yang  Fengxiang Lu
Affiliation:1. Department of Cardiology, Zhongda Hospital & School of Clinical Medicine, Southeast University, Nanjing 210009,China
2. Department of Cardiology, the First Affiliated Hospital of Nanjing Medical University, Nanjing 210009, China
Abstract:Objective Assessment of right ventricular function in patients with atrial septal defect (ASD) is difficult. The Doppler myocardial performance index (MPI) may provide a method of assessing function in these patients. The purposes of this study were to evaluate the right ventricular function and its changes in patients with ASD after transcatheter closure of ASD. Methods MPI, defined as the sum of isovolumic relaxation time and isovolumic contraction time derived by ejection time, was measured from tricuspid inflow and right ventricular outflow; Doppler velocity profiles recorded during routine echocardiography. Twenty nine patients ( 13 men, 16 women;mean age 25.28 ± 12.69, range 6 to 57 years) were diagnosed to secundum ASD [the stretched diameters of ASD were from 9 To 36 (24.91 ±7.98) mm], and had a successfully placed Amplatzer septal occluder (ASO) (the sizes of ASO were from 11 to 40 mm ); there were 81 sex-matched, age-matched healthy people (control group 41men, 40 women; mean age 29.02 ± 14.22, range 4 to 45 years).MPI was measured again on 3 days and 1 month after closure of ASD. Change in the study group was assessed and compared to the control subjects with structurally normal hearts. A complete 2- dimensional and Doppler echocardiographic examination was performed in all study groups. Results 1) The isovolumic relaxation and isovolumic contraction times [respectively(77.59 ± 14.39)ms vs (60.93 ± 12.94)ms, P<0.0001; (28.28 ± 10.88)ms vs (23.64 ± 9.01)ms, P=0.027] were prolonged, and ejection time [(260.65 ± 21.86 )ms vs (271.85 ± 21.92)ms, P=0.033] was shortened in patients with ASD compared with that in control subjects, resulting in a marked increase in the MPI(0.40 ± 0.07 vs 0.31 ± 0.05, P<0.0001) from normal values; 2) by Pearson's correlations, the MPI had no correlation with heart rate and blood pressure in control subjects and patients with ASD, but it correlated positively with age in patients with ASD; 3) by Pearson's correlations, the MPI correlated positively with the diameter of ASD and pulmonary artery pressure; 4) after transcatheter closure of ASD, the MPI decreased markedly. Conclusions 1) MPI is a conceptually new, simple, and reproducible Doppler index in patients with ASD; 2) MPI is free from the effect of age, heart rate and blood pressure; (3) MPI appears to be relatively dependent on changes in the diameter of ASD and pulmonary artery pressure; 4) the right ventricular function was improved after transcatheter closure of ASD.
Keywords:heart  atrial septal defect  right ventricular function  myocardial performance index
本文献已被 维普 万方数据 等数据库收录!
点击此处可从《老年心脏病学杂志》浏览原始摘要信息
点击此处可从《老年心脏病学杂志》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号