首页 | 本学科首页   官方微博 | 高级检索  
     


Time-driven activity-based costing of a novel form of CT-guided high-dose-rate brachytherapy intraoperative radiation therapy compared with conventional breast intraoperative radiation therapy for early stage breast cancer
Affiliation:1. Department of Radiation Oncology, University of Virginia School of Medicine, Charlottesville, VA;2. Department of Radiation Medicine, Georgetown University School of Medicine, Washington, DC;3. Division of Breast and Melanoma Surgery, Department of Surgery, University of Virginia School of Medicine, Charlottesville, VA;4. Department of Public Health Sciences, University of Virginia School of Medicine, Charlottesville, VA
Abstract:IntroductionIntraoperative radiation therapy is an emerging option for adjuvant therapy for early stage breast cancer, although it is not currently considered standard of care in the United States. We applied time-driven activity-based costing to compare two alternative methods of breast intraoperative radiation therapy, including treatment similar to the techniques employed in the TARGIT-A clinical trial and a novel version with CT-guidance and high-dose-rate (HRD) brachytherapy.Methods and MaterialsProcess maps were created to describe the steps required to deliver intraoperative radiation therapy for early stage breast cancer at each institution. The components of intraoperative radiation therapy included personnel, equipment, and consumable supplies. The capacity cost rate was determined for each resource. Based on this, the delivery costs were calculated for each regimen. For comparison across centers, we did not account for indirect facilities costs and interinstitutional differences in personnel salaries.ResultsThe CT-guided, HRD form of intraoperative radiation therapy costs more to deliver ($4,126.21) than the conventional method studied in the TARGIT-A trial ($1,070.45). The cost of the brachytherapy balloon applicator ($2,750) was the primary driver of the estimated differences in costs. Consumable supplies were the largest contributor to the brachytherapy-based approach, whereas personnel costs were the largest contributor to costs of the standard form of intraoperative radiation therapy.ConclusionsWhen compared with the more established method of intraoperative radiation therapy using a portable superficial photon unit, the delivery of treatment with CT guidance and HDR brachytherapy is associated with substantially higher costs. The excess costs are driven primarily by the cost of the disposable brachytherapy balloon applicator and, to a lesser extent, additional personnel costs. Future work should include evaluation of a less expensive brachytherapy applicator to increase the anticipated value of brachytherapy-based intraoperative radiation therapy.
Keywords:Intraoperative radiation therapy  Breast cancer  Time-driven activity-based costing  Brachytherapy  High-dose-rate
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号