Usefulness of Cranial Ultrasound for Detecting Neonatal Middle Cerebral Artery Stroke |
| |
Authors: | Gemma Olivé Thais Agut Carlos Mario Echeverría-Palacio Gemma Arca Alfredo García-Alix |
| |
Affiliation: | 2. Research Group “Neuroped-UNAL,” School of Medicine, Universidad Nacional de Colombia, Bogotá, Columbia;3. Department of Neonatology, Agrupació Sanitaria Hospital Clinic, Hospital Sant Joan de Déu, University of Barcelona, Barcelona, Spain;4. CIBER de Enfermedades Raras (CIBERER), U724, Madrid, Spain |
| |
Abstract: | Magnetic resonance imaging is the gold standard technique in establishing the diagnosis of neonatal arterial ischemic stroke (NAIS). The diagnostic value of cranial ultrasound scanning in this clinical context is controversial. We aimed to assess the current sensitivity of the cranial ultrasound scan (CUS) in detecting NAIS, as this issue has not been well described in the literature. Newborns with NAIS diagnosed by magnetic resonance imaging between 2010 and 2016 were included. All CUSs were blindly analyzed retrospectively by a neonatologist expert in neuroimaging and compared with the findings of non-expert evaluators recorded on medical charts immediately after performing the evaluation. The overall sensitivity of CUS in detecting an imaging finding suggestive of NAIS was 87% (95% confidence interval (CI): 79%–95%) for an expert evaluator, but declined to 72% (61%–83%) when performed by a non-expert evaluator (p 0.002). Sensitivity was 83% and 61% in the first 24 h and 86% and 66% at 24–48 h for expert and non-expert evaluators, respectively (p < 0.05). CUS has higher sensitivity than previously reported in the detection of a NAIS, for both expert and non-expert evaluators. These findings may be explained by the advanced technology of new ultrasound equipment. Expertise in performing CUS is useful, particularly in the first 48 h after clinical debut. |
| |
Keywords: | Neonatal arterial ischemic stroke Cranial ultrasound Neonate Sensitivity |
本文献已被 ScienceDirect 等数据库收录! |
|