首页 | 本学科首页   官方微博 | 高级检索  
     

两种测量软件在杏仁核体积测量中的比较
引用本文:潘克梫,陈楠,王星,李坤成,卓彦. 两种测量软件在杏仁核体积测量中的比较[J]. 中国医学影像技术, 2009, 25(5): 890-893
作者姓名:潘克梫  陈楠  王星  李坤成  卓彦
作者单位:1. 首都医科大学宣武医院放射科,北京,100053
2. 中国科学院生物物理研究所脑与认知科学国家重点实验室,北京,100101
基金项目:国家高技术研究发展计划(863计划),科技部资助项目,国家自然科学基金,中国科学院知识创新工程项目 
摘    要:目的 对比分析Midob(Mi)与Aquariusws(Aq)测量软件在MR图像上测量杏仁核体积的应用.方法 在T1加权三维磁化强度预备梯度回波序列大脑MR图像上,用Mi和Aq测量软件分别测量31名健康成年人双侧杏仁核的体积,并对体积指标进行标准化处理.结果 高分辨率MR三维图像应用不同的测量软件能分辨杏仁核界限,两种测量软件所得杏仁核体积差异无统计学意义(t=0.77,P>0.05).结论 Mi和Aq测量软件对杏仁核体积测量一致性高,适于临床推广应用.

关 键 词:杏仁核  磁共振成像  人体测量术
收稿时间:2009-01-08
修稿时间:2009-01-16

Comparative study of amygdala volumetric measurementsbetween Midob and Aquariusws software
PAN Ke-qin,CHEN Nan,WANG Xing,LI Kun-cheng and ZHUO Yan. Comparative study of amygdala volumetric measurementsbetween Midob and Aquariusws software[J]. Chinese Journal of Medical Imaging Technology, 2009, 25(5): 890-893
Authors:PAN Ke-qin  CHEN Nan  WANG Xing  LI Kun-cheng  ZHUO Yan
Affiliation:Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing 100053, China;Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing 100053, China;Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing 100053, China;Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing 100053, China;State Key Laboratory of Brain and Cognitive Science, Institute of Biophysics, Chinese Academyof Sciences, Beijing 100101, China
Abstract:Objective To compare the discriminative ability of MRI volumetric amygdala measurements between Midob (Mi) and Aquariusws (Aq) measuring software, and to evaluate their clinical value for amygdala measurements. Methods The study group consisted of 31 healthy control subjects. Mi and Aq volumetric measurements of the bilateral amygdala formations, amygdala volumes were performed on the serial reconstructed MR images. Discriminant analysis was used to identify measurements independently contributing to discriminating between Mi and Aq subjects. Results All amygdala measurements of 31 healthy control subjects were no significantly different between Mi and Aq volumetric measurements (t=0.77, P>0.05). Conclusion Mi and Aq volumetric measuring software of MRI amygdala structures have high consistency, and both software are suitable for clinical application.
Keywords:Amygdala  Magnetic resonance imaging  Anthropometry
本文献已被 维普 万方数据 等数据库收录!
点击此处可从《中国医学影像技术》浏览原始摘要信息
点击此处可从《中国医学影像技术》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号