首页 | 本学科首页   官方微博 | 高级检索  
检索        

光学相干断层成像评价不同类型药物洗脱支架置入术后的内膜覆盖
作者姓名:Tian F  Chen YD  Chen L  Sun ZJ  Liu HB  Liu CF  Guo J  Wang JD
作者单位:解放军总医院心内科,北京,100853
摘    要:目的 应用光学相干断层成像(OCT)对比不同类型药物洗脱支架(DES)置入后的内膜覆盖情况.方法 入选62例在我院置入DES(15.3±5.7)个月后行OCT检查的患者,依据置入支架类型分为Cypher支架组(病例数=26,支架数=57)、Endeavor支架组(病例数=17,支架数=23)和Firebird支架组(病...

关 键 词:冠状动脉疾病  支架  体层摄影术  光学相干  增生

Evaluation on the neointimal coverage post drug-eluting stent implantation by optical coherence tomography
Tian F,Chen YD,Chen L,Sun ZJ,Liu HB,Liu CF,Guo J,Wang JD.Evaluation on the neointimal coverage post drug-eluting stent implantation by optical coherence tomography[J].Chinese Journal of Cardiology,2011,39(3):204-207.
Authors:Tian Feng  Chen Yun-Dai  Chen Lian  Sun Zhi-Jun  Liu Hong-Bin  Liu Chang-Fu  Guo Jun  Wang Jin-da
Institution:Cardiovascular Department, Chinese People's Liberation Army General Hospital, Beijing 100853, China.
Abstract:Objective To assess the neointimal coverage after the implantation of various drug eluting stents (DES) by optical coherence tomography ( OCT). Methods The study comprised of 62 patients implanted DES for ( 15. 3 ± 5.7 ) months. Patients were divided into three groups according to the type of implanted stent: Cypher group ( patient = 26, stent = 57 ), Endeavor group ( patient = 17, stent = 23 )and Firebird group (patient = 19, stent = 32). OCT images of the stent were analyzed by software equipped by Light Lab system. Intimal thickness of 64 μm, 168 μm and 366 μm represents 10%, 25% and 50%lumen area loss, respectively. Neointimal coverage was thin with intimal thickness≤64 μm, satisfactory with intimal thickness between 65 μm and 366 μm and hyperplaisa and restenosis with intimal thickness > 366μm. Results The percent of complete neointimal coverage was similar among groups ( P > 0. 05 ). The thickness of neointimal coverage in Cypher and Endeavor and Firebird group was (178.7 ± 11.9)μm,(228.7 ± 17. 1 ) μm and ( 170. 3 ± 13.3 ) μm, respectively( all P < 0. 05 ). The symmetry of Cypher stent was better than Firebird stent, and the symmetry of Firebird stent was better than Endeavoe stent. Conclusion There was significant difference on neointimal coverage after various types of DES implantation, and OCT can be used to evaluate the symmetry of neointimal coverage post implantation of various DES.
Keywords:Coronary disease  Stents  Tomography  optical coherence  Hyperplasia
本文献已被 万方数据 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号