首页 | 本学科首页   官方微博 | 高级检索  
     


Evaluation of the safety of anterior capsule staining with trypan blue under air: a retrospective analysis
Authors:Young Min Park  Jong Soo Lee  Ji Eun Lee  Yeon Ji Jo  Ik Soo Byon  Sung Who Park
Affiliation:Centum Bright Light Eye Clinic, 20, Centum 2-ro, Haeundae-gu, Busan, Korea 48060, Republic of Korea,Department of Ophthalmology, School of Medicine, Pusan National University and Medical Research Institute, Pusan 49241, Republic of Korea,Department of Ophthalmology, School of Medicine, Pusan National University and Medical Research Institute, Pusan 49241, Republic of Korea,Department of Ophthalmology, School of Medicine, Pusan National University and Medical Research Institute, Pusan 49241, Republic of Korea,Department of Ophthalmology, School of Medicine, Pusan National University and Medical Research Institute, Pusan 49241, Republic of Korea and Department of Ophthalmology, School of Medicine, Pusan National University and Medical Research Institute, Pusan 49241, Republic of Korea
Abstract:AIM: To evaluate the safety of using 0.03% trypan blue under air for anterior capsule staining in cataract surgery.METHODS: The current study involved a retrospective analysis of the medical records of 86 patients with vitreous hemorrhage, who underwent pars plana vitrectomy and cataract surgery. The patients were classified into two groups. The trypan blue group (n=45) comprised patients who underwent anterior capsule staining with 0.03% trypan blue under an air bubble. The control group (n=41) comprised of patients who underwent intracameral illuminator-assisted capsulorhexis. The status of endothelial cell density (ECD) in both the groups was analyzed.RESULTS: The trypan blue group displayed significant decline in ECD at 1mo (7.91% loss, P<0.001) and 3mo (9.65% loss, P<0.001) after the surgery, whereas no significant changes were observed in the control group. Moreover, the number of patients who did not display a postoperative decline in ECD was significantly higher in the control group (43.9%; 18 patients) than in the trypan blue group (17.1%; 7 patients, P=0.004).CONCLUSION: Anterior capsule staining with trypan blue under the air bubble would not be as safe as the intracameral illuminator. The ECD loss might be attributed to the air bubble rather than to the deleterious effects of 0.03% trypan blue. Further studies are required to clarify this.
Keywords:anterior capsule   cataract   endothelium   trypan blue   vitreous hemorrhage
点击此处可从《国际眼科》浏览原始摘要信息
点击此处可从《国际眼科》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号