首页 | 本学科首页   官方微博 | 高级检索  
     

高效液相离子对色谱法测定糖尿病大鼠血浆中二甲双胍浓度及其药代动力学研究(英文)
引用本文:陈烨,李汉青,许娇娇,酒向飞,邓晨辉,李新刚,李良,徐小晴,周田彦,卢炜. 高效液相离子对色谱法测定糖尿病大鼠血浆中二甲双胍浓度及其药代动力学研究(英文)[J]. 中国药学, 2012, 21(3): 211-218. DOI: 10.5246/jcps.2012.03.027
作者姓名:陈烨  李汉青  许娇娇  酒向飞  邓晨辉  李新刚  李良  徐小晴  周田彦  卢炜
作者单位:北京大学医学部药学院药剂学系;北京大学医学部天然药物及仿生药物国家重点实验室
基金项目:National Integrity Innovational Technology Platform of New Drug and Research and Development (Grant No.2009ZX09201-010);Innovation Team of Ministry of Education(Grant No. BMU20110263)
摘    要:本研究建立并验证了测定糖尿病大鼠血浆中二甲双胍浓度的高效液相色谱方法,以阿替洛尔为内标,加入10%高氯酸沉淀蛋白来制备血浆样品。色谱条件:AQ-C18极限色谱柱(250mm×4.6mm,5μm),流动相(pH5.05)为乙腈-水(31:69,v/v,水相中含有0.002M十二烷基磺酸钠,0.0125M磷酸二氢钾,0.015M三乙胺),流速1.0mL/min。二甲双胍在7.5-4000ng/mL范围内具有良好的线性关系(r>0.994),最低检测限(LLOQ)为7.5ng/mL,描述精密度的相对标准偏差(RSD)范围为1.87%-15.70%,准确度为93.98%-106.89%。二甲双胍和内标的回收率分别为95.40%和95.31%。不同实验条件下质控样品的稳定性相对偏差范围在±9.00%之内。该方法成功地运用到糖尿病大鼠单剂量灌胃10mg/kg二甲双胍后的药代动力学研究中,结果显示本研究采用AQ-C18极限色谱柱建立的离子对色谱法对强极性化合物如二甲双胍具有良好的分离效果。

关 键 词:二甲双胍  离子对高效液相色谱  糖尿病大鼠血浆  药代动力学  AQ-C18极限色谱柱

Determination of metformin in diabetic rat plasma by an improved ion-pair high-performance liquid chromatography: application to a pharmacokinetic study
Ye Chen,Han-Qing Li,Jiao-Jiao Xu,Xiang-Fei Jiu,Chen-Hui Deng,Xin-Gang Li,Liang Li,Xiao-Qing Xu,Tian-Yan Zhou, Wei Lu. Determination of metformin in diabetic rat plasma by an improved ion-pair high-performance liquid chromatography: application to a pharmacokinetic study[J]. Journal of Chinese Pharmaceutical Sciences, 2012, 21(3): 211-218. DOI: 10.5246/jcps.2012.03.027
Authors:Ye Chen  Han-Qing Li  Jiao-Jiao Xu  Xiang-Fei Jiu  Chen-Hui Deng  Xin-Gang Li  Liang Li  Xiao-Qing Xu  Tian-Yan Zhou   Wei Lu
Affiliation:1,2* 1. State Key Laboratory of Natural and Biomimetic Drugs, Peking University Health Science Center, Beijing 100191, China 2. Department of Pharmaceutics, School of Pharmaceutical Science, Peking University Health Science Center, Beijing 100191, China
Abstract:An efficient and sensitive ion-pair HPLC-UV method using atenolol as internal standard (IS) was developed and validated for the determination of metformin in the plasma of diabetic rats. Plasma samples were deproteinated with 10% (v/v) perchloric acid. Separation was achieved on a UltimateTM AQ-C18 column (250 mm×4.6 mm, 5 μm) with a mobile phase (pH 5.05) composed of acetonitrile–water (31:69, v/v, containing 0.002 M sodium dodecyl sulfate, 0.0125 M potassium dihydrogen phosphate, 0.015 M triethylamine) at a flow rate of 1.0 mL/min. The calibration curve was linear (r>0.994) between 7.5 and 4000 ng/mL. The lower limit of quantification (LLOQ) was 7.5 ng/mL. The precision was validated and the relative standard deviation was in the range of 1.87% to 15.70%; the accuracy was between 93.98%–106.89%. The mean recoveries were 95.40% and 95.31% for metformin and IS, respectively. The relative error (RE) of stability at different storage conditions was within ±9.00%. This method was used to determine the concentration-time profile of metformin in diabetic rat plasma following an oral administration of metformin at the dose of 10 mg/kg. Our results indicated that ion-pair HPLC-UV method using UltimateTM AQ-C18 column was effective for the pharmacokinetic studies of high polarity compounds like metformin.
Keywords:Metformin  Ion-pair HPLC  Diabetic rat plasma  Pharmacokinetics  UltimateTM AQ-C18
本文献已被 CNKI 等数据库收录!
点击此处可从《中国药学》浏览原始摘要信息
点击此处可从《中国药学》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏