Indoor air quality and health problems associated with damp floor coverings
Authors:Anneli?Tuomainen  author-information"  >  author-information__contact u-icon-before"  >  mailto:anneli.tuomainen@ttl.fi"   title="  anneli.tuomainen@ttl.fi"   itemprop="  email"   data-track="  click"   data-track-action="  Email author"   data-track-label="  "  >Email author,Markku?Seuri,Anne?Sieppi
Affiliation:(1) Department of Occupational Hygiene and Toxicology, Kuopio Regional Institute of Occupational Health, POB 93, 70701 Kuopio, Finland;(2) Department of Occupational Medicine, Kuopio Regional Institute of Occupational Health, Kuopio, Finland;(3) Medivire Occupational Health Centre, Kuopio, Finland
Abstract:Objectives To study the relationship between a high incidence of bronchial asthma among employees working in an office building and an indoor air problem related to the degradation of polyvinyl chloride (PVC) floor coverings in the building. The indoor air measurements and results of renovations are also described.Methods Employeesrsquo symptoms were surveyed by a questionnaire, and the incidence of asthma was calculated from the medical records for 1997–2000. The quality of indoor air was assessed by microbial sampling and by investigation of the building for possible moisture damage. Indoor air was sampled for volatile organic compounds (VOCs) through Tenax adsorbent tubes. In situ volatile emission measurements from the concrete floor were performed via the field and laboratory emission cell (FLEC) method.Results In an office with approximately 150 employees, eight new cases of asthma were found in 4 years. In addition, the workers complained of respiratory, conjunctival and nasal symptoms. Emissions indicating the degradation of plastic floor coverings (e.g. 2-ethyl-1-hexanol, 1-butanol) were found in the indoor air and floor material samples. The plastic floor coverings, adhesives and the levelling layers were carefully removed from 12 rooms. The VOCs had diffused into the underlying concrete slabs. The concrete was warmed to remove the diffused VOCs from these areas. After the repairs the concentrations of the VOCs indicating the degradation of PVC, decreased, as did the prevalence of the employeesrsquo symptoms and several asthma patientsrsquo need for medication.Conclusions The workers in the office building complained of several respiratory, conjunctival and dermal symptoms. The incidence of adult-onset asthma was approximately nine-times higher than that among Finns employed in similar work. The most probable single cause of the indoor air problem was the degradation of the plastic floor coverings.
Keywords:Indoor air  PVC  Chemical impurities  Asthma
本文献已被 PubMed SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号