首页 | 本学科首页   官方微博 | 高级检索  
     

^99mTc—MIBI与^99mTc—PPM肺肿瘤阳性显像的对比研究
引用本文:卢献平 陈锡龙. ^99mTc—MIBI与^99mTc—PPM肺肿瘤阳性显像的对比研究[J]. 中国临床医学影像杂志, 1999, 10(4): 233-235
作者姓名:卢献平 陈锡龙
作者单位:[1]中山医科大学涵逸仙纪念医院核医学科广东 [2]中山医科大学孙逸仙纪念医院心内科广东
摘    要:目的:对比分析^99mTc-甲氧基异丁基异腈(MIBI)与^99mTc-培普利欧霉素(PPM)肺肿瘤显像的特点与诊断效能。方法:对48例使用^99mTc-MIBI与39例使用^99cTc-PPM肿瘤阳性显像的结果通过目测观察,T/N(肿瘤与非肿瘤)比值测定,储存指数RI测定,延迟显像摄取指数DUI测定并对其结果进行对比。结果:目测观察,^909mTc-MIBI显像对恶性肿瘤诊断的灵敏度为94.12

关 键 词:肺肿瘤 肿瘤多耐药基因 Tc99m-MIBI

Compare the effectiveness of scintigraphy in technetium-99m-sestamibi with in technetium-99m-peplomycin in patients with benign and malignant lesion in the lung
LU Xian-ping, JIANG Ning-yi, CHEN Xi-long,LIANG Jiu-gen,LIU Sheng,ZHANG Hua,SHAO Ji-shu,CHEN Shao-xiong,LIU Xing-guang. Compare the effectiveness of scintigraphy in technetium-99m-sestamibi with in technetium-99m-peplomycin in patients with benign and malignant lesion in the lung[J]. Journal of China Clinic Medical Imaging, 1999, 10(4): 233-235
Authors:LU Xian-ping   JIANG Ning-yi   CHEN Xi-long  LIANG Jiu-gen  LIU Sheng  ZHANG Hua  SHAO Ji-shu  CHEN Shao-xiong  LIU Xing-guang
Abstract:Objective: To compare the effectiveness of scintigraphy in technetium - 99m - sestamibi (MIBI) with in technetium - 99m -peplomycin(PPM) in patients with benign and malignant lesion in the lung.Methods: The scintigraphy was performed with technetium99m-MIBI in 48 patients and technetium - 99m - PPM in 39 patients with pulmonary lesions .In this study, the imagin results were analyzed and the early and delayed tumor - to - normal lung uptake raio(T/N)were measaured and the retention index(RI) and the delayed uptake index(DUI) were calculated.Then above Parameters were compared between in technetium - 99m - MIBI and in technetium - 99m -PPM. Results: The sensitivity, specificity and accuuacy for technetium - 99m - MIBI scintigraphy were 94. 12%, 85. 71 % and 91. 67%, fortechnetium - 99m - PPM scintigraphy 90. 91 %, 83. 33% and 89. 74%. There was no significant difference in the sensitivity, specificity andaccuracy among the two scintigraphys(P > 0. 05). In malignant lesion group, the early T/N, delayed T/N, RI and DUI for technetium -99m - MIBl scintigraphy were 1. 36, 1. 37, 0. 74 and 1. 38, for technetiam - 99m - PPM scintgraphy 1.13, 1. 36, 11. 77 and 1. 64. Therewas no significant difference in the early T/N and delayed T/N among the two scintigraphys(P > 0.05) and there was significant low in RI (P< 0. 01) and DUI (P < 0. 05)for technetium - 99m - MIBI scintigraphy that wer compared with those for technetium - 99m - PPM scintigraphy. In the benign lesion group, there was no significant difference in the early T/N, delayed T/N, RI and DUI between in technetium -99m - MIBI scintigraphy and in technetitun - 99m - PPM scintigraphy(P > 0. 05). Conclusions: The both scintgraphys in technetium -99m - MIBl and in technetium - 99m - PPM seem to be good candidaet for noninvasive methods to diagnose pulmonary neoplasm and to distinguish between benign and malignant lesion in the lung.Some lung neoplasm cells extruded more technetium - 99m - MIBI than technetium - 99m - PPM.
Keywords:Lung neoplasm  Technetium-99m-sestamibi  Technetium-99m-peplomycin  Drug resistance   neoplasm
本文献已被 CNKI 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号