A dosimetric comparative study between conformal and intensity modulated radiation therapy in the treatment of primary nasopharyngeal carcinomas: the Egyptian experience
Ehsan G. El-Ghoneimy,Mohamed A. Hassan,Mahmoud F. El-Bestar,Omar M. Othman,Karim N. Mashhour. A dosimetric comparative study between conformal and intensity modulated radiation therapy in the treatment of primary nasopharyngeal carcinomas: the Egyptian experience[J]. The Chinese-German Journal of Clinical Oncology, 2012, 11(11): 626-631. DOI: 10.1007/s10330-012-1040-7
Authors:Ehsan G. El-Ghoneimy  Mohamed A. Hassan  Mahmoud F. El-Bestar  Omar M. Othman  Karim N. Mashhour
Affiliation:1. Department of Clinical Oncology, Kasr Al-Einy School of Medicine, Cairo University, Cairo, Egypt
2. Department of Oto-Rhino-Laryngology, Kasr Al-Einy School of Medicine, Cairo University, Cairo, Egypt
3. Department of Radiology, Kasr Al-Einy School of Medicine, Cairo University, Cairo, Egypt
Abstract:

Objective

The study is a comparative study, the aim of which is to compare 3D conformal radiation therapy (3DCRT) and intensity modulated radiation therapy (IMRT) in treating nasopharyngeal carcinomas; dosimetrically evaluating and comparing both techniques as regard target coverage and doses to organs at risk (OAR).

Methods

Twenty patients with nasopharyngeal carcinoma were treated by 3D-CRT technique and another 20 patients were treated by IMRT. A dosimetric comparison was done by performing two plans for the same patient using Eclipse planning system (version 8.6).

Results

IMRT had a better tumor coverage and conformity index compared to 3D-CRT plans (P value of 0.001 and 0.004), respectively. As for the dose homogeneity it was also better in the IMRT plans and the reason for this was attributed to the dose inhomogeneity at the photon/electron junction in the 3D-CRT plans (P value 0.032). Also, doses received by the risk structures, particularly parotids, was significantly less in the IMRT plans than those of 3D-CRT (P value 0.001).

Conclusion

IMRT technique was clearly able to increase the dose delivery to the target volume, improve conformity and homogeneity index and spare the parotid glands in comparison to 3D-CRT technique.
Keywords: