首页 | 本学科首页   官方微博 | 高级检索  
     

UF-100尿沉渣分析仪、干化学分析仪与镜检联合检测的应用
引用本文:殷海芳. UF-100尿沉渣分析仪、干化学分析仪与镜检联合检测的应用[J]. 海南医学院学报, 2011, 17(2): 264-266
作者姓名:殷海芳
作者单位:北京市顺义区医院检验科,北京,101300
基金项目:海南医学院科研基金学报项目
摘    要:目的:探讨UF-100尿沉渣分析仪、干化学分析仪与镜检3种方法联合检测管形、尿蛋白的重要性.方法:2 771例尿标本分别用UF-100尿沉渣分析仪、干化学分析仪和Olympus显微镜检测管形、尿蛋白,并且对3种方法的结果进行比较分析.结果:3种方法比较:(1)沉渣法管形阴性、干化学法蛋白阴性、镜检法管形阴性占45.87...

关 键 词:管形  蛋白  镜检  尿沉渣分析仪法  干化学分析仪法

Combined use of UF-100 automated urinalysis analyzer, dry chemistry analyzer and microscopy for urinary detection
YIN Hai-fang. Combined use of UF-100 automated urinalysis analyzer, dry chemistry analyzer and microscopy for urinary detection[J]. Journal of Hainan Medical College, 2011, 17(2): 264-266
Authors:YIN Hai-fang
Affiliation:YIN Hai-fang(Laboratory Department,Shunyi District Hospital in Beijing,Shunyi 101300,China)
Abstract:Objective: To show the importance of combined use of UF-100 automated urinalysis analyzer,dry chemistry analyzer and microscopy for detection of tubular cells and proteins in urine samples.Methods: A total of 2771 urine samples were detected with UF-100 automated urinalysis analyzer,dry chemistry analyzer and microscopy;respectively,and efficiency of these three methods were shown.Results:(1) 45.8% samples were shown as negative for tubular cells by UF-100 automated urinalysis analyzer,negative for protein by dry chemistry analyzer, and negative for tubular cells under microscopy: respectively. (2) 14.69% samples were shown as positive for tubular cells by UF-100 automated urinalysis analyzer, positive for protein by dry chemistry analyzer, and positive for tubular cells under microscopy; respectively. (3) 5.4% samples were shown as negative for tubular cells by UF-100 automated urinalysis analyzer, positive for protein by dry chemistry analyzer, and negative for tubular cells under mlcroscopy: respectively. (4) 0.73% samples were shown as negative for tubular cells by UF-100 automated urinalysis analyzer, positive for protein by dry chemistry analyzer, and posiuve for tubular cells under mmroscopy: respectively. (5) 23.42% samples were shown as positive for tubular cells by UF-100 automated urinalysis analyzer, positive for protem by dry chemistry analyzer, and negauve for tubular ceils under mmroscopy: respectively. (6) 9.82% samples were shown as negative for tubular cells by UF-100 automated urinalysis analyzer, positive for protein by dry chemistry analyzer, and negative for tubular cells under mmroscopy~ respectively. (7) 0.07% samples were shown as negative for tubular ceils by UF-100 automated urinalysis analyzer, negative for protein by dry chemistry analyzer, and positwe for tubular cells under mmroscopy; respectively. Detection results were unanimous for 60. 56% samples, and false positive and negative results revealed by UF-100 automated urinalysis analyzer, dry chemistry analyzer were 23.42% vs 24.5% and0.79 vs 9.89%. Conclusions: Due to complex composition of urine samples, both UF-100 automated urinalysis analyzer and dry chemistry analyzer may produce false results. Itrs highly recommended that urine samples should be detected by both UF 100 automated urinalysis analyzer and dry chemistry analyzer, further detection under microscopy is necessary in case one of them show positive result.
Keywords:Tubular cell; Protein; Microscopy; Urine sediment analyzer; Dry chemistry analyzer;
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号