如何防止灭菌化学指示卡监测中的失误
引用本文:陈国华,沈喜珍.如何防止灭菌化学指示卡监测中的失误[J].中华护理杂志,1998(5).
作者姓名:陈国华  沈喜珍
作者单位:南通医学院附属医院
摘    要:压力蒸气灭菌化学指示卡监测是常规使用的灭菌效果监测措施之一,但有其限局性,如指示卡安放位置或监测方法不正确,会产生假性结果,导致判断失误。作者对此进行了试验研究,结果表明:只有在工艺、化学、生物三种监测结果均合格时,方能判定为无菌物品

关 键 词:化学指示卡  假性结果  监测

Prevention of the Mistakes Caused by Sterilization Indicator
Chen Guo hua,Shen Xi zhen // Chinese Journal of Nursing,.Prevention of the Mistakes Caused by Sterilization Indicator[J].Chinese Journal of Nursing,1998(5).
Authors:Chen Guo hua  Shen Xi zhen // Chinese Journal of Nursing  
Abstract:In order to observe sterilization result,the chemical card was used routinely as indicator in pressure steam sterilization.But there is limitation to this method.If the card is put at a wrong site or the method you operated is incorrect,the consqaence of the indicator would be false and disturb your observation.Result from experiment indicated that when technical,chemical and biological tests meet the standard of sterilization,the result is reliable. Author's address \ Hospital Attached to Nantong Medical,Natong Jiangsu Zibo
Keywords:Chemical indicator card \ False consqaence \ Monitor  