超声在筛检大鼠肝泡状棘球蚴病模型中的应用价值
引用本文:朱帝文,任伟新,顾俊鹏,许晓冬,张海潇.超声在筛检大鼠肝泡状棘球蚴病模型中的应用价值[J].中国医学影像技术,2009,25(3):363-365.
作者姓名:朱帝文  任伟新  顾俊鹏  许晓冬  张海潇
作者单位:新疆医科大学第一附属医院影像中心DSA室,新疆,乌鲁木齐,830054
摘    要:目的 评价超声在筛检大鼠肝泡状棘球蚴病模型中的应用价值.方法 采用经皮肝脏穿刺注射泡状棘球蚴组织混悬液的方法,制备原发性HAE模型,40只Wistar大鼠接种6个月后行B超检查及开腹探查.结果 B超检查示21只大鼠感染泡状棘球蚴,19只未感染,感染率52.50%.开腹探查证实B超检查21只阳性中1只未感染,19只未感染中1只为阳性.B超检查的灵敏度为95.24%,特异性为94.74%,假阳性率为4.27%,假阴性率5.27%.结论 B超检查诊断大鼠肝泡状棘球蚴感染的灵敏度及特异度均较高,可做为一种无创性筛选大鼠肝泡状棘球蚴感染的方法.

关 键 词:棘球蚴病    模型  动物  超声检查
收稿时间:2008/10/17 0:00:00
修稿时间:2008/11/24 0:00:00

Application value of ultrasound in screening hepatic echinococcusmultiloculars in Wistar rats
ZHU Di-wen,REN Wei-xin,GU Jun-peng,XU Xiao-dong and ZHANG Hai-xiao.Application value of ultrasound in screening hepatic echinococcusmultiloculars in Wistar rats[J].Chinese Journal of Medical Imaging Technology,2009,25(3):363-365.
Authors:ZHU Di-wen  REN Wei-xin  GU Jun-peng  XU Xiao-dong and ZHANG Hai-xiao
Institution:DSA Room of Imaging Center, the First Affiliated Hospital of Xinjiang Medical University, Urumqi 830054, China;DSA Room of Imaging Center, the First Affiliated Hospital of Xinjiang Medical University, Urumqi 830054, China;DSA Room of Imaging Center, the First Affiliated Hospital of Xinjiang Medical University, Urumqi 830054, China;DSA Room of Imaging Center, the First Affiliated Hospital of Xinjiang Medical University, Urumqi 830054, China;DSA Room of Imaging Center, the First Affiliated Hospital of Xinjiang Medical University, Urumqi 830054, China
Abstract:Objective To assess the value of ultrasound as a non-invasive method for identifying the model of hepatic alveolar echinococcosis (HAE) in Wistar rats. Methods Forty primary HAE models were set up by means of percutaneous transhepatic injection of echinococcus multiloculars suspension into the liver of Wistar rats, and the rats were inspected with B-mode ultrasound and laparotomy after six months. Results B-mode ultrasound displayed 21 Wistar rats (52.50%) were infected with alveolar echinococcosis, while one of them was proved uninfected by laparotomy. One of 19 uninfected rats detected by B-mode ultrasound was proved infected by laparotomy. The sensitivity, specificity, false positive rate and false negative rate of B-mode ultrasound was 95.24%, 94.74%, 4.27% and 5.27%, respectively. Conclusion B-mode ultrasound inspection is a suitable non-invasive way to screen the infection of Wistar rats model with HAE.
Keywords:Echinococcosis  hepatic  Models  animal  Ultrasonography