首页 | 本学科首页   官方微博 | 高级检索  
     


Robotic Laparoendoscopic Single-Site Surgery Using GelPort as the Access Platform
Authors:Robert J. Stein  Wesley M. WhiteRaj K. Goel  Brian H. IrwinGeorge Pascal Haber  Jihad H. Kaouk
Affiliation:Glickman Urologic and Kidney Institute, Cleveland Clinic, Cleveland, OH, USA
Abstract:

Background

Laparoendoscopic single-site surgery (LESS) allows for the performance of major urologic procedures with a single small incision and minimal scarring. The da Vinci Surgical System provides advantages of easy articulation and improved ergonomics; however, an ideal platform for these procedures has not been identified.

Objective

To evaluate the GelPort laparoscopic system as an access platform for robotic LESS (R-LESS) procedures.

Design, setting, and participants

Since April 2008, 11 R-LESS procedures have been completed successfully in a single institutional referral center. For the last four consecutive cases, the GelPort has been used as an access platform through a 2.5–5-cm umbilical incision.

Intervention

R-LESS cases performed with the GelPort included pyeloplasty (n = 2), radical nephrectomy (n = 1), and partial nephrectomy (n = 1).

Measurements

Perioperative data were obtained for all patients including demographic data, operative indications, operative records, length of stay, complications, and pathologic analysis.

Results and limitations

For both pyeloplasty cases, average operative time (OR time) was 235 min and estimated blood loss (EBL) was 38 cm3. For the patient undergoing radical nephrectomy for a 5.1-cm renal tumor, OR time was 200 min and EBL was 250 cm3. The final patient underwent partial nephrectomy without renal hilar clamping for an 11-cm angiomyolipoma with OR time of 180 min and EBL of 600 cm3. All R-LESS procedures attempted with the GelPort were completed successfully and without complication. Average length of hospital stay was 1.75 d (range: 1–2). The partial nephrectomy patient required transfusion of 1 U of packed red blood cells.

Conclusions

Use of the GelPort as an access platform for R-LESS procedures provides adequate spacing and flexibility of port placement and acceptable access to the surgical field for the assistant, especially during procedures that require a specimen extraction incision. Additional platform and instrumentation development will likely simplify R-LESS procedures further as experience grows.
Keywords:Da Vinci   Laparoscopic   Laparoscopy   LESS   Nephrectomy   NOTES   Partial nephrectomy   Pyeloplasty   Reconstructive   Robot   Robotic   Single access   Single port
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏