Apicoaortic bypass using a vascular graft with a bioprosthetic valve
Authors:Yasuhiro Fujii  Kazushige Kanki  Hideya Mitsui  Kozo Ishino  Hiroshi Izumoto  Shunji Sano
Affiliation:(1) Department of Cardiovascular Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Science, 2-5-1 Shikatacho, Okayama 700-8558, Japan
Abstract:We report a case of 75-year-old man who underwent an apicoaortic bypass for severe aortic stenosis. The patient had a porcelain aorta accompanied by a severely calcified aortic annulus. We used a woven polyester vascular graft instead of a rigid apical connector because the latter material cannot be obtained in Japan. Postoperative examination showed no compression or stenosis in the apical outflow. A woven polyester vascular graft is therefore considered suitable for an apicoaortic bypass.
Keywords:Aortic valve stenosis  Heart valve prosthesis implantation  Aorta  Thoracic