摘    要:目的:报告脑保护装置在颈动脉和椎动脉粥样硬化性狭窄血管内扩张和支架置入术中的初步应用结果。方法:应用脑保护装置filterwire(滤网导丝),或angioguard(血管保护伞),对18例21处颈动脉和椎动脉粥样硬化性狭窄行血管内扩张和(或)支架置入术,并总结其临床使用结果。结果:应用脑保护装置成功施行21例次颈动脉和椎动脉狭窄血管内扩张和(或)支架置入术,介入操作方便易行,无术中和术后并发症发生。结论:脑保护装置有助于降低颈动脉和椎动脉狭窄血管内扩张和支架置入术中动脉粥样斑块或附壁血栓脱落性脑梗死的发生,提高其治疗安全性。

关 键 词:支架置入术 颈动脉狭窄 椎底动脉供血不足 气囊血管成形术 脑保护装置

Initial application of brain protection device in dilatation and stenting of carotid and vertebral artery stenosis
Wang Daming,Sheng Aizhen,Gong Tao,Yang Chongqing,Zhai Lele,Wang Zuowei,Liu Yinhong,Liu Fang,Han Jingfen,Wang Yulin,Sun Jing,Li Jin,Liu Shushan. Initial application of brain protection device in dilatation and stenting of carotid and vertebral artery stenosis[J]. Chinese Journal of Surgery, 2002, 40(12): 893-895,I002
Authors:Wang Daming  Sheng Aizhen  Gong Tao  Yang Chongqing  Zhai Lele  Wang Zuowei  Liu Yinhong  Liu Fang  Han Jingfen  Wang Yulin  Sun Jing  Li Jin  Liu Shushan
Affiliation:Department of Neurosurgery, Beijing Hospital Ministry of Health, Beijing 100730, China.
Abstract:Objective To report the initial application of brain protection device in the dilatation and stenting of atherosclerotic stenosis of the carotid and vertebral artery. Methods Eighteen patients with 21 atherosclerotic stenoses of the carotid or vertebral artery underwent dilatation and/or stenting with brain protection device (filterwire or angioguard). The clinical results were summarized and the indispensability and feasibility of the device was discussed. Results With the aid of brain protection device, endovascular dilatation and (or) stenting were performed in all the patients with 21 stenoses of the carotid or vertebral artery. The interventional manipulation was successful and no complications occurred. Conclusions Brain protection device is helpful to decrease the embolic complication caused by atherosclerotic plaque and thromboembolus and to increase the security of interventional therapy, during the dilatation and/or stenting of stenosis of the carotid or vertebral artery.
Keywords:Carotid stenosis  Vertebrobasilar insufficiency  Angioplasty   balloon  Stenting  Brain protection device