首页 | 本学科首页   官方微博 | 高级检索  
     


Repeatability of visual function measures in age-related macular degeneration
Authors:Tariq Aslam  Sajjad Mahmood  Konstantinos Balaskas  Niall Patton  Rajeev G. Tanawade  Shi Zhuan Tan  Stephen A. Roberts  Jeremy Parkes  Paul N. Bishop
Affiliation:1. Manchester Royal Eye Hospital, Manchester Academic Health Science Centre, Manchester, UK
3. Centre for Ophthalmology and Vision Research, Institute of Human Development, University of Manchester, Oxford Road, Manchester, UK
5. Moorfields Eye Hospital NHS Foundation Trust, City Road, London, UK
4. Centre for Biostatistics, Institute of Population Health, University of Manchester, Oxford Road, Manchester, UK
2. Centre for Advanced Discovery and Experimental Therapeutics (CADET), Central Manchester University Hospitals NHS Foundation Trust, Manchester Academic Health Science Centre, Manchester, UK
Abstract:

Purpose

To assess repeatability of visual function measures in patients with early, intermediate or late age-related macular degeneration (AMD) without active neovascular disease in the study eye, but active neovascular AMD in the fellow eye.

Methods

One hundred subjects from an ongoing trial were screened for this study in which their LogMAR acuity, contrast sensitivity and reading performance were assessed using standardised protocols by trained optometrists. The same measures were repeated one month later and repeatability of the visual functions assessed.

Results

Data from 83 subjects satisfied inclusion criteria for analysis. Coefficient of repeatability was 14.9 letters for LogMAR visual acuity , 7.2 letters for Pelli Robson contrast sensitivity, 0.72 for LogMAR reading acuity, 110.4 words/ min for reading speed and 0.67 for LogMAR critical print size. Intraclass correlation coefficients allowed comparison between measures and were found to be 0.96 for LogMAR visual acuity, 0.93 for contrast sensitivity, 0.75 for LogMAR reading acuity, 0.79 for reading speed and 0.74 for LogMAR critical print size. Coefficients of variation were 9.4 %, 10.7 %, 48.4 %, 28.4 % and 31.8 % respectively.

Conclusions

We found coefficients of repeatability that concurred with previous studies demonstrating variability of visual functions in patients with AMD. In addition, we found intraclass correlation coefficients to be better with visual acuity and contrast sensitivity than with measures of reading performance.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏