超微血流显像在甲状腺微小结节诊断中的应用价值分析
引用本文:高梅华,杨莲,张卫卫.超微血流显像在甲状腺微小结节诊断中的应用价值分析[J].癌症进展,2017,15(3).
作者姓名:高梅华  杨莲  张卫卫
作者单位:洪湖市人民医院超声影像科,湖北 洪湖,433200;洪湖市人民医院超声外科,湖北 洪湖,433200
摘    要:目的 研究超微血流显像(SMI)在甲状腺微小结节(TSN)诊断中的应用价值.方法 选择136例TSN患者,结节数目169个,先行二维超声及彩色多普勒超声检查,发现可疑结节后启动SMI、彩色多普勒血流显像(CDFI)模式进行诊断,比较SMI、CDFI诊断TSN良恶性的敏感度、特异度、阳性预测值、阴性预测值,以及SMI、CDFI模式下良恶性TSN的血流分级和血供分型.结果 经病理检查,169个结节中,恶性结节97个(57.40%),良性结节72个(42.60%).以病理检查结果为金标准,SMI诊断TSN良恶性的敏感度(92.78%)、特异度(95.83%)、阳性预测值(96.77%)、阴性预测值(90.79%)均高于CDFI诊断的敏感度(82.47%)、特异度(80.56%)、阳性预测值(85.11%)、阴性预测值(77.33%).SMI模式下良性TSN血流检出率(88.89%)高于CDFI模式(68.05%),恶性TSN血流检出率(52.58%)低于CDFI模式(71.13%),差异均有统计学意义(P﹤0.05).SMI、CDFI模式下良恶性TSN的血流分级和血供分型比较,差异均有统计学意义(P﹤0.05).结论 SMI可有效判断微小血管及低速血流,准确观察微细血管,敏感度、特异度及血流检出率均较高,在TSN良恶性的辅助诊断上具有较高的应用价值.

关 键 词:微血流显像  彩色多普勒血流显像  甲状腺微小结节  诊断  应用价值

Application of superb microvascular imaging in the diagnosis of thyroid nodules
GAO Meihua,YANG Lian,ZHANG Weiwei.Application of superb microvascular imaging in the diagnosis of thyroid nodules[J].Oncology Progress,2017,15(3).
Authors:GAO Meihua  YANG Lian  ZHANG Weiwei
Abstract:Objective To study the diagnostic value of superb microvascular imaging (SMI) in thyroid small nodules (TSN). Method 136 cases of TSN patients, with a total of 169 nodules, were initially examined by 2D ultrasound and color Doppler ultrasound, while the SMI and color doppler flow imaging (CDFI) were performed for diagnosis of suspect-ed nodules, and then the SMI and CDFI were compared for sensitivity, specificity, as well as positive predictive value and negative predictive value in detecting benign/malignant TSN, of which the blood flow and blood supply detected using SMI and CDFI were analyzed. Result Of the 169 nodules, 97 (57.40%) malignant nodules, and 72 (42.60%) benign nod-ules were confirmed pathologically. Taking pathological findings as the gold standard, the SMI determined benign or ma-lignant TSN with higher sensitivity (92.78%), specificity (95.83%), positive predictive value (96.77%), and negative pre-dictive value (90.79%) than the CDFI mode sensitivity (82.47%), specificity (80.56%), positive predictive value (85.11%), negative predictive value (77.33%), respectively]. The detection rate of blood flow (88.89%) in benign TSN was higher using SMI vs using CDFI (68.05%), while that in malignant TSN was lower in SMI (52.58%) compared with CDFI (71.13%) (P<0.05). Overall, SMI and CDFI were significantly different in respect of detecting the blood flow and blood supply for benign and malignant TSN (P<0.05). Conclusion SMI can effectively distinguish microvessels and low-velocity blood flow, facilitating accurate observation of microvessels, with acceptable sensitivity, specificity and de-tection rate of blood flow, and is highly applicable for adjuvant diagnosis of benign or malignant TSN.
Keywords:superb mircovascular imaging  color Doppler flow imaging  thyroid small nodule  diagnosis  application value