首页 | 本学科首页   官方微博 | 高级检索  
     

多模态影像技术评价冠状动脉微循环障碍模型的实验研究
引用本文:吕宇航,籍庆余,吕成,李猛,于德东,李洪宇,高燕峰,何鑫,王松海,董馨,韩瑞娟,吕滨,孙凯. 多模态影像技术评价冠状动脉微循环障碍模型的实验研究[J]. 中华放射学杂志, 2021, 0(2): 196-202
作者姓名:吕宇航  籍庆余  吕成  李猛  于德东  李洪宇  高燕峰  何鑫  王松海  董馨  韩瑞娟  吕滨  孙凯
作者单位:内蒙古医科大学包头临床医学院;海口市中医医院放射科;中国医学科学院中关村医院放射科;中国医学科学院阜外医院放射科;中国医学科学院阜外医院深圳医院放射科
基金项目:国家重点研发计划(2016YFC1300401);国家自然科学基金(81560286)。
摘    要:目的:探讨多模态影像技术评价山羊动物模型冠状动脉微循环障碍(CMD)的价值。方法:雌雄不限,按5~8月龄随机挑选实验用萨能奶山羊10只。麻醉后经股动脉选择性插管,于不同分支冠状动脉远端缓慢注入1 ml单分散聚苯乙烯微球混合液(含微球计数约1.14×10 6/ml),建立CMD动物模型。成功建模7 d后行双能...

关 键 词:体层摄影术,X 线计算机  正电子,发射型体层摄影术  单光子,发射型体层摄影术  磁共振成像  冠状动脉疾病

Evaluation on coronary microcirculation disorder model using multimodal imaging technology: an experimental study
Lyu Yuhang,Ji Qingyu,Lyu Cheng,Li Meng,Yu Dedong,Li Hongyu,Gao Yanfeng,He Xin,Wang Songhai,Dong Xin,Han Ruijuan,Lyu Bin,Sun Kai. Evaluation on coronary microcirculation disorder model using multimodal imaging technology: an experimental study[J]. Chinese Journal of Radiology, 2021, 0(2): 196-202
Authors:Lyu Yuhang  Ji Qingyu  Lyu Cheng  Li Meng  Yu Dedong  Li Hongyu  Gao Yanfeng  He Xin  Wang Songhai  Dong Xin  Han Ruijuan  Lyu Bin  Sun Kai
Affiliation:(Baotou Clinical Medical College,Inner Mongolia Medical University,Baotou 014040,China;Department of Radiology,Haikou Hospital of Traditional Chinese Medicine,Haikou 570216,China;Department of Radiology,Zhongguancun Hospital,Chinese Academy of Medical Sciences,Beijing 100190,China;Department of Radiology,Fuwai Hospital,Chinese Academy of Medical Sciences,Beijing 100037,China;Department of Radiology,Fuwai Hospital Shenzhen Hospital of Chinese Academy of Medical Sciences,Shenzhen 518057,China)
Abstract:Objective To explore the value of multimodal imaging for evaluation on coronary microcirculation disorders in a goat animal model of CMD.Methods Ten Saanen dairy goats age of 5-8 months were randomly selected in this experimental study.After anesthesia,a 1.9-F micro guide wire was introduced via a percutaneous direct puncture through superficial femoral artery.Then,1 ml of monodisperse polystyrene microsphere mixture,which contained 1.14×106/ml of microsphere,was slowly injected into the distal end of branch coronary to establish a CMD animal model.DECT-MPI,SPECT-MPI,PET-MPI,CMR-MPI imaging examinations were performed 7 days after the establishment of CMD model.The animals were sacrificed for myocardial histopathological examination after the imaging examination.Using histopathology as the standard,the sensitivity,specificity,positive predictive value,negative predictive value and accuracy of the DECT-MPI,SPECT-MPI,PET-MPI,CMR-MPI imaging were evaluated.The ROC curve is used to evaluate the value of the imaging methods in the diagnosis of CMD.Results Of the 10 experimental animals,three goats died,and CMD model was successfully established in 7 goats.A total of 119 myocardial segments were evaluated on histopathology,of which,18 myocardial segments were confirmed ischemic myocardial segments and 101 myocardial segments were normal.Taking the results of pathology as standard,the sensitivity and specificity of DECT-MPI,SPECT-MPI,PET-MPI in diagnosing CMD were 55.56%and 98.02%,66.75%and 98.83%,93.75%and 97.68%,respectively.Due to the long operation time of MRI and the requirement of longer anesthesia time,only one experimental animal successfully completed the MR examination with the accuracy rate of 88.24%.Conclusions Our experimental study provides a goat model of CME using monodisperse polystyrene microsphere mixture injection resembling the clinical scenario of CME.DECT-MPI,SPECT-MPI,PET-MPI and CMR-MPI showed good performance for evaluation on CMD,with different advantages and limitations for each modality.
Keywords:Tomography,X-ray computed  Positron,emission tomography  Single photon,emission tomography  Magnetic resonance imaging  Coronary artery disease
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号