首页 | 本学科首页   官方微博 | 高级检索  
检索        


Optimizing Imaging Quality and Radiation Dose by the Age-Dependent Setting of Tube Voltage in Pediatric Chest Digital Radiography
Authors:Hui Guo  Wen-Ya Liu  Xiao-Ye He  Xiao-Shan Zhou  Qun-Li Zeng  Bai-Yan Li
Institution:Xinjiang Medical University, Affiliated Hospital 1, Medical Imaging Research Center, Urumqi 830054, China.
Abstract:

Objective

The quality and radiation dose of different tube voltage sets for chest digital radiography (DR) were compared in a series of pediatric age groups.

Materials and Methods

Forty-five hundred children aged 0-14 years (yr) were randomly divided into four groups according to the tube voltage protocols for chest DR: lower kilovoltage potential (kVp) (A), intermediate kVp (B), and higher kVp (C) groups, and the fixed high kVp group (controls). The results were analyzed among five different age groups (0-1 yr, 1-3 yr, 3-7 yr, 7-11 yr and 11-14 yr). The dose area product (DAP) and visual grading analysis score (VGAS) were determined and compared by using one-way analysis of variance.

Results

The mean DAP of protocol C was significantly lower as compared with protocols A, B and controls (p < 0.05). DAP was higher in protocol A than the controls (p <0.001), but it was not statistically significantly different between B and the controls (p = 0.976). Mean VGAS was lower in the controls than all three protocols (p < 0.001 for all). Mean VGAS did not differ between protocols A and B (p = 0.334), but was lower in protocol C than A (p = 0.008) and B (p = 0.049).

Conclusion

Protocol C (higher kVp) may help optimize the trade-off between radiation dose and image quality, and it may be acceptable for use in a pediatric age group from these results.
Keywords:Digital radiography  Children  Chest  Dose area product  Visual grading analysis score
设为首页 | 免责声明 | 关于勤云 | 加入收藏