首页 | 本学科首页   官方微博 | 高级检索  
检索        

脑肿瘤磁敏感对比MR灌注成像技术方法的研究
引用本文:张皓,沈天真,陈星荣.脑肿瘤磁敏感对比MR灌注成像技术方法的研究[J].中国医学计算机成像杂志,2002,8(5):289-293.
作者姓名:张皓  沈天真  陈星荣
作者单位:200040,复旦大学华山医院放射科
摘    要:研究动态敏感对比MR灌注技术在脑肿瘤研究中的应用技术和某些限制。材料和方法 :使用GEsigna1.5TMR扫描仪对本院20例头颈部疾病患者(未见颅内病变而需增强扫描者)及30例脑肿瘤患者(均经术后病理证实)进行常规平扫加增强MR检查同时使用SEEPI和GEEPI序列进行快速团注造影剂后MR灌注扫描。获得资料经在线工作站后处理分析。结果 :所有病例均获得相应功能图像及信号时间曲线 ,经肘正中静脉注射者45例均获得较为理想的功能图像及时间信号曲线。其余5例经腕表浅静脉及股静脉注射者曲线不完整。1例冠状位成像者图像变形。脂肪抑制预扫描及TR=1800ms ,TE=40ms ,FLIP角=60°的GEEPI序列为脑肿瘤灌注研究较为理想的选择。结论 :正确应用动态敏感对比MR灌注技术对脑部疾病进行定性及半定量研究 ,基本可以满足临床工作的需要

关 键 词:磁共振成像  灌注  脑肿瘤  磁敏感

Technological Strategies of the Dynamic Susceptibility Contrast MR Perfusion Imaging in Brain Tumors
Zhang Hao,Shen Tianzhen,Chen Xingrong.Technological Strategies of the Dynamic Susceptibility Contrast MR Perfusion Imaging in Brain Tumors[J].Chinese Computed Medical Imaging,2002,8(5):289-293.
Authors:Zhang Hao  Shen Tianzhen  Chen Xingrong
Institution:Zhang Hao,Shen Tianzhen,Chen XingrongDepartment of Radiology,Huashan Hospital,Shanghai 200040
Abstract:Purpose:To study the dynamic susceptibility contrast (DSC)MR perfusion technological strategies in clinical use and its limits.Materials and Methods:Thirty brain tumor patients(10 meningiomas,15 gliomas and 5 brain metastasis tumors) and 20 controls(without intro-skull disease but need enhancement) were undergone DSC MR imaging after a routine MR scanning in a 1.5T clinical MR scanner(GE Medical System,USA).GD-DTPA were used as contrast agent;different doses and injection methods were studied;SE EPI?GE EPI sequences were used in perfusion examinations.After perfusion examination,routine enhanced T1WI MR imaging with exact copy of perfusion slice selection was performed in every patient for image fusion and post-processing.All raw data were sent to and handled with on-line working station afterward.Results:All cases got functional rCBV,rCBF,MTT and TTP images and time-signal curves;45 cases with bolus injection of GD-DTPA in middle elbow vein got ideal function images and curves,no significant statistic difference with different trace doses(10ml and 20ml).The other 5 cases injected in wrist veins and femur vein got irregular curves;1 patient doing coronal perfusion imaging got deformed function images.Fat suppressed GE EPI sequence(TR=1800ms,TE=40ms,FLIP angle=60) is most favorable for brain tumor perfusion studies.Conclusion:Correct use of DSC MR perfusion technological strategies while examining patients with brain tumors can fulfill clinical needs of quality and half-quantity measurements.
Keywords:Magnetic resonance imaging Perfusion Brain tumor  
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号