Evaluation of Rate-Responsive Pacemakers by Transesophageal Holter Monitoring of Spontaneous Atrial Rate
Authors:MARIA GRAZIA BONGIORNI  EZIO SOLDATI  LUCA PAPERINI  REA POZZOLINI  DIANORA LEVORATO  GIUSEPPE ARENA  PAOLO PISTELLI  GIANLUCA QUIRINO  REA BIAGINI  CARLO CONTINI
Institution:The CNR, Institute of Clinical Physiology, Pisa, Italy
Abstract:BONGIORNI, M.G., ET AL.: Evaluation of Rate-Responsive Pacemakers by Transesophageal Holter Monitoring of Spontaneous Atrial Rate. One of the most important problems in rate responsive (RR) pacing is the clinical experimental evaluation of the reliability of various sensors. In particular, it is difficult to test their sensitivity and specificity during daily activity of the patients. Atrial rate, when present and normal, is the most physiological marker of metabolic requirements, but sometimes it is impossible to analyze the P wave in ventricular paced rhythm during routinely performed tests (e.g., ergometric test and 24-hour Holter monitoring). During various physical activities, we monitored atrial electrograms on an esophageal lead on the first channel of a standard Holter tape recorder; on the second channel a surface ECG lead was recorded. We selected 10 patients with high grade heart block and normal sinus node function paced in RR-VVI mode. RR pacing was obtained using various sensors (body activity, blood temperature, spike-T interval, minute ventilation). The good quality of recording allowed an easy evaluation of atrial and ventricular rates. In four cases an appropriate increase in heart rate was documented; sensitivity threshold and/or rate response slope were reprogrammed when indicated. The pacing rate of one patient did not parallel the atrial rate during walking only. In three cases, we observed a delay in the ventricular rate increase, with ventricular rate decreasing at peak exercise despite further atrial rate increase. In the last two patients, we observed inappropriate pacing response; pacing rate increased later and to a lower level than the atrial one. This new method is applied easily and appears reliable to evaluate the response of RR pacemakers to individual metabolic needs. Its applicability is, however, limited by the need for a normal sinus node function. In conclusion, transesophageal atrial rate recording is a useful tool for the clinical evaluation of RR pacemakers, and it can be proposed as a new method for testing new sensors.
Keywords:rate responsive pacing  transesophageal recording  sinus node activity
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号